    Errors in Cross-Correlation Peak Location

    Source: Journal of Dynamic Systems, Measurement, and Control:;1982:;volume( 104 ):;issue: 002::page 194
    Author:
    G. D. Lassahn
    ,
    A. G. Baker
    DOI: 10.1115/1.3139696
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A method for determining the uncertainty in the location of a cross-correlation peak is derived and two examples are examined. When a cross-correlation peak location is used in transit time flowmeters as a measurement technique for fluid-flow velocity, turbulence in the fluid increases the peak location uncertainty. This effect is examined for two models of turbulence. Also examined is the bias or shift in the peak location due to time response or filter mismatch.
    • Download: (521.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Errors in Cross-Correlation Peak Location

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/95628
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorG. D. Lassahn
    contributor authorA. G. Baker
    date accessioned2017-05-08T23:12:57Z
    date available2017-05-08T23:12:57Z
    date copyrightJune, 1982
    date issued1982
    identifier issn0022-0434
    identifier otherJDSMAA-26071#194_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/95628
    description abstractA method for determining the uncertainty in the location of a cross-correlation peak is derived and two examples are examined. When a cross-correlation peak location is used in transit time flowmeters as a measurement technique for fluid-flow velocity, turbulence in the fluid increases the peak location uncertainty. This effect is examined for two models of turbulence. Also examined is the bias or shift in the peak location due to time response or filter mismatch.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleErrors in Cross-Correlation Peak Location
    typeJournal Paper
    journal volume104
    journal issue2
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.3139696
    journal fristpage194
    journal lastpage199
    identifier eissn1528-9028
    treeJournal of Dynamic Systems, Measurement, and Control:;1982:;volume( 104 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian