    Contact Stability and Contact Safety of a Magnetic Resonance Imaging-Guided Robotic Catheter Under Heart Surface Motion

    Source: Journal of Dynamic Systems, Measurement, and Control:;2021:;volume( 143 ):;issue: 007::page 071010-1
    Author:
    Hao, Ran
    ,
    Erdem Tuna, E.
    ,
    Çavuşoğlu, M. Cenk
    DOI: 10.1115/1.4049837
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Contact force quality is one of the most critical factors for safe and effective lesion formation during catheter based atrial fibrillation ablation procedures. In this paper, the contact stability and contact safety of a novel magnetic resonance imaging (MRI)-actuated robotic cardiac ablation catheter subject to surface motion disturbances are studied. First, a quasi-static contact force optimization algorithm, which calculates the actuation needed to achieve a desired contact force at an instantaneous tissue surface configuration is introduced. This algorithm is then generalized using a least-squares formulation to optimize the contact stability and safety over a prediction horizon for a given estimated heart motion trajectory. Four contact force control schemes are proposed based on these algorithms. The first proposed force control scheme employs instantaneous heart position feedback. The second control scheme applies a constant actuation level using a quasi-periodic heart motion prediction. The third and the last contact force control schemes employ a generalized adaptive filter-based heart motion prediction, where the former uses the predicted instantaneous position feedback, and the latter is a receding horizon controller. The performance of the proposed control schemes is compared and evaluated in a simulation environment.
    • Download: (1.229Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Contact Stability and Contact Safety of a Magnetic Resonance Imaging-Guided Robotic Catheter Under Heart Surface Motion

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277134
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorHao, Ran
    contributor authorErdem Tuna, E.
    contributor authorÇavuşoğlu, M. Cenk
    date accessioned2022-02-05T22:12:47Z
    date available2022-02-05T22:12:47Z
    date copyright2/23/2021 12:00:00 AM
    date issued2021
    identifier issn0022-0434
    identifier otherds_143_07_071010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277134
    description abstractContact force quality is one of the most critical factors for safe and effective lesion formation during catheter based atrial fibrillation ablation procedures. In this paper, the contact stability and contact safety of a novel magnetic resonance imaging (MRI)-actuated robotic cardiac ablation catheter subject to surface motion disturbances are studied. First, a quasi-static contact force optimization algorithm, which calculates the actuation needed to achieve a desired contact force at an instantaneous tissue surface configuration is introduced. This algorithm is then generalized using a least-squares formulation to optimize the contact stability and safety over a prediction horizon for a given estimated heart motion trajectory. Four contact force control schemes are proposed based on these algorithms. The first proposed force control scheme employs instantaneous heart position feedback. The second control scheme applies a constant actuation level using a quasi-periodic heart motion prediction. The third and the last contact force control schemes employ a generalized adaptive filter-based heart motion prediction, where the former uses the predicted instantaneous position feedback, and the latter is a receding horizon controller. The performance of the proposed control schemes is compared and evaluated in a simulation environment.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleContact Stability and Contact Safety of a Magnetic Resonance Imaging-Guided Robotic Catheter Under Heart Surface Motion
    typeJournal Paper
    journal volume143
    journal issue7
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.4049837
    journal fristpage071010-1
    journal lastpage071010-10
    page10
    treeJournal of Dynamic Systems, Measurement, and Control:;2021:;volume( 143 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian