YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Applied Mechanics
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Applied Mechanics
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Identification of Static Loading Conditions Using Piezoelectric Sensor Arrays

    Source: Journal of Applied Mechanics:;2018:;volume( 085 ):;issue: 001::page 11008
    Author:
    Zhang, He
    ,
    Shen, Mingzhou
    ,
    Zhang, Yangyang
    ,
    Chen, Yisheng
    ,
    Lü, Chaofeng
    DOI: 10.1115/1.4038426
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: To make sure the safety, durability, and serviceability of structures in-service, health monitoring systems (HMS) are widely used in management of civil infrastructures in recent years. Compared with traditional force sensors, lead zirconium titanate (PZT) sensor performs better in smart sensing in HMS with advantages of high sensitivity, self-powering and fast response to highly dynamic load. Here, we propose to utilize PZT sensor arrays to identify the position and magnitude of external loads that are applied on a simply supported beam. An identification method is proposed based on experimental tests and theoretical electromechanical analyses, which is proved effective by comparing the identified parameters with the actually applied loading conditions and signals recorded by commercial force sensors. Experimental observations also reveal that PZT sensors respond faster to loading process than commercial force sensor, which makes it qualified in identification of transient loading such as impact processing in loading history. Results also demonstrate the applicability of the method to identify multiple concentrated load and the average moving speed of the applied load. The current method may provide a useful tool for identifying load conditions on various beam structures.
    • Download: (1.829Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Identification of Static Loading Conditions Using Piezoelectric Sensor Arrays

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4252776
    Collections
    • Journal of Applied Mechanics

    Show full item record

    contributor authorZhang, He
    contributor authorShen, Mingzhou
    contributor authorZhang, Yangyang
    contributor authorChen, Yisheng
    contributor authorLü, Chaofeng
    date accessioned2019-02-28T11:06:36Z
    date available2019-02-28T11:06:36Z
    date copyright11/28/2017 12:00:00 AM
    date issued2018
    identifier issn0021-8936
    identifier otherjam_085_01_011008.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252776
    description abstractTo make sure the safety, durability, and serviceability of structures in-service, health monitoring systems (HMS) are widely used in management of civil infrastructures in recent years. Compared with traditional force sensors, lead zirconium titanate (PZT) sensor performs better in smart sensing in HMS with advantages of high sensitivity, self-powering and fast response to highly dynamic load. Here, we propose to utilize PZT sensor arrays to identify the position and magnitude of external loads that are applied on a simply supported beam. An identification method is proposed based on experimental tests and theoretical electromechanical analyses, which is proved effective by comparing the identified parameters with the actually applied loading conditions and signals recorded by commercial force sensors. Experimental observations also reveal that PZT sensors respond faster to loading process than commercial force sensor, which makes it qualified in identification of transient loading such as impact processing in loading history. Results also demonstrate the applicability of the method to identify multiple concentrated load and the average moving speed of the applied load. The current method may provide a useful tool for identifying load conditions on various beam structures.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleIdentification of Static Loading Conditions Using Piezoelectric Sensor Arrays
    typeJournal Paper
    journal volume85
    journal issue1
    journal titleJournal of Applied Mechanics
    identifier doi10.1115/1.4038426
    journal fristpage11008
    journal lastpage011008-7
    treeJournal of Applied Mechanics:;2018:;volume( 085 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian