YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Electronic Packaging
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Electronic Packaging
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Transient Data Processing of Flow Boiling Local Heat Transfer in a Multi-Microchannel Evaporator Under a Heat Flux Disturbance

    Source: Journal of Electronic Packaging:;2017:;volume( 139 ):;issue: 001::page 11005
    Author:
    Huang, Houxue
    ,
    Lamaison, Nicolas
    ,
    Thome, John R.
    DOI: 10.1115/1.4035386
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Multi-microchannel evaporators are often used to cool down electronic devices subjected to continuous heat load variations. However, so far, rare studies have addressed the transient flow boiling local heat transfer data occurring in such applications. The present paper introduces and compares two different data reduction methods for transient flow boiling data in a multi-microchannel evaporator. A transient test of heat disturbance from 20 to 30 W cm−2 was conducted in a multi-microchannel evaporator using R236fa as the test fluid. The test section was 1 × 1 cm2 in size and had 67 channels, each having a cross-sectional area of 100 × 100 μm2. The micro-evaporator backside temperature was obtained with a fine-resolution infrared (IR) camera. The first data reduction method (referred to three-dimensional (3D)-TDMA) consists in solving a transient 3D inverse heat conduction problem by using a tridiagonal matrix algorithm (TDMA), a Newton–Raphson iteration, and a local energy balance method. The second method (referred to two-dimensional (2D)-controlled) considers only 2D conduction in the substrate of the micro-evaporator and solves at each time step the well-posed 2D conduction problem using a semi-implicit solver. It is shown that the first method is more accurate, while the second one reduces significantly the computational time but led to an approximated solution. This is mainly due to the 2D assumption used in the second method without considering heat conduction in the widthwise direction of the micro-evaporator.
    • Download: (4.177Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Transient Data Processing of Flow Boiling Local Heat Transfer in a Multi-Microchannel Evaporator Under a Heat Flux Disturbance

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4236837
    Collections
    • Journal of Electronic Packaging

    Show full item record

    contributor authorHuang, Houxue
    contributor authorLamaison, Nicolas
    contributor authorThome, John R.
    date accessioned2017-11-25T07:21:01Z
    date available2017-11-25T07:21:01Z
    date copyright2017/5/1
    date issued2017
    identifier issn1043-7398
    identifier otherep_139_01_011005.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4236837
    description abstractMulti-microchannel evaporators are often used to cool down electronic devices subjected to continuous heat load variations. However, so far, rare studies have addressed the transient flow boiling local heat transfer data occurring in such applications. The present paper introduces and compares two different data reduction methods for transient flow boiling data in a multi-microchannel evaporator. A transient test of heat disturbance from 20 to 30 W cm−2 was conducted in a multi-microchannel evaporator using R236fa as the test fluid. The test section was 1 × 1 cm2 in size and had 67 channels, each having a cross-sectional area of 100 × 100 μm2. The micro-evaporator backside temperature was obtained with a fine-resolution infrared (IR) camera. The first data reduction method (referred to three-dimensional (3D)-TDMA) consists in solving a transient 3D inverse heat conduction problem by using a tridiagonal matrix algorithm (TDMA), a Newton–Raphson iteration, and a local energy balance method. The second method (referred to two-dimensional (2D)-controlled) considers only 2D conduction in the substrate of the micro-evaporator and solves at each time step the well-posed 2D conduction problem using a semi-implicit solver. It is shown that the first method is more accurate, while the second one reduces significantly the computational time but led to an approximated solution. This is mainly due to the 2D assumption used in the second method without considering heat conduction in the widthwise direction of the micro-evaporator.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTransient Data Processing of Flow Boiling Local Heat Transfer in a Multi-Microchannel Evaporator Under a Heat Flux Disturbance
    typeJournal Paper
    journal volume139
    journal issue1
    journal titleJournal of Electronic Packaging
    identifier doi10.1115/1.4035386
    journal fristpage11005
    journal lastpage011005-10
    treeJournal of Electronic Packaging:;2017:;volume( 139 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian