contributor author | Jalali, Ali | |
contributor author | Rehman, Mohamed | |
contributor author | Lingappan, Arul | |
contributor author | Nataraj, C. | |
date accessioned | 2017-05-09T01:27:19Z | |
date available | 2017-05-09T01:27:19Z | |
date issued | 2016 | |
identifier issn | 0022-0434 | |
identifier other | ds_138_11_111013.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/160762 | |
description abstract | This paper is concerned with the mathematical modeling and detection of endotracheal (ET) intubation in children under general anesthesia during surgery. In major pediatric surgeries, the airway is often secured with an endotracheal tube (ETT) followed by initiation of mechanical ventilation. Clinicians utilize auscultation of breath sounds and capnography to verify correct ETT placement. However, anesthesia providers often delay timely charting of ET intubation. This latency in event documentation results in decreased efficacy of clinical decision support systems. In order to target this problem, we collected real inpatient data and designed an algorithm to accurately detect the intubation time within the clinically valid range; the results show that we are able to achieve high accuracy in more than 96% of the cases. Automatic detection of ET intubation time would thus enhance better realtime data capture to support future improvement in clinical decision support systems. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Automatic Detection of Endotracheal Intubation During the Anesthesia Procedure | |
type | Journal Paper | |
journal volume | 138 | |
journal issue | 11 | |
journal title | Journal of Dynamic Systems, Measurement, and Control | |
identifier doi | 10.1115/1.4033864 | |
journal fristpage | 111013 | |
journal lastpage | 111013 | |
identifier eissn | 1528-9028 | |
tree | Journal of Dynamic Systems, Measurement, and Control:;2016:;volume( 138 ):;issue: 011 | |
contenttype | Fulltext | |