Experimental Characterization of Various Cold Aisle Containment Configurations for Data CentersSource: Journal of Electronic Packaging:;2015:;volume( 137 ):;issue: 001::page 11007DOI: 10.1115/1.4028520Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The data center industry has experienced significant growth over the last decade, mainly due to the increased use of the internet for our day to day activities such as ecommerce, social media, video streaming, and healthcare. This growth in demand results in higher energy costs, as data centers can be energy intensive facilities. A significant portion of the energy used in data centers is for cooling purposes. Hence, it is one of the important areas of optimization to be addressed to create more efficient data centers. Among the many ways to increase data center efficiencies, air flow management is a key solution to many existing data centers. Fundamentally, there are three main schemes: hotaisle containment, coldaisle containment, and exhaust chimney containment. This paper's focus is to experimentally characterize the following cold aisle configurations: open aisle, partially contained aisle, and fully contained aisles. Experimental data presented to evaluate the effectiveness of the different configurations are rack inlet contour plots, tile and rack flow rates, pressure measurements, and server central processing unit (CPU) temperatures.
|
Collections
Show full item record
| contributor author | Sundaralingam, Vikneshan | |
| contributor author | Arghode, Vaibhav K. | |
| contributor author | Joshi, Yogendra | |
| contributor author | Phelps, Wally | |
| date accessioned | 2017-05-09T01:16:54Z | |
| date available | 2017-05-09T01:16:54Z | |
| date issued | 2015 | |
| identifier issn | 1528-9044 | |
| identifier other | ep_137_01_011007.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/157664 | |
| description abstract | The data center industry has experienced significant growth over the last decade, mainly due to the increased use of the internet for our day to day activities such as ecommerce, social media, video streaming, and healthcare. This growth in demand results in higher energy costs, as data centers can be energy intensive facilities. A significant portion of the energy used in data centers is for cooling purposes. Hence, it is one of the important areas of optimization to be addressed to create more efficient data centers. Among the many ways to increase data center efficiencies, air flow management is a key solution to many existing data centers. Fundamentally, there are three main schemes: hotaisle containment, coldaisle containment, and exhaust chimney containment. This paper's focus is to experimentally characterize the following cold aisle configurations: open aisle, partially contained aisle, and fully contained aisles. Experimental data presented to evaluate the effectiveness of the different configurations are rack inlet contour plots, tile and rack flow rates, pressure measurements, and server central processing unit (CPU) temperatures. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Experimental Characterization of Various Cold Aisle Containment Configurations for Data Centers | |
| type | Journal Paper | |
| journal volume | 137 | |
| journal issue | 1 | |
| journal title | Journal of Electronic Packaging | |
| identifier doi | 10.1115/1.4028520 | |
| journal fristpage | 11007 | |
| journal lastpage | 11007 | |
| identifier eissn | 1043-7398 | |
| tree | Journal of Electronic Packaging:;2015:;volume( 137 ):;issue: 001 | |
| contenttype | Fulltext |