    Overspray and Interstage Fog Cooling in Gas Turbine Compressor Using Stage-Stacking Scheme—Part II: Case Study

    Source: Journal of Thermal Science and Engineering Applications:;2010:;volume( 002 ):;issue: 003::page 31002
    Author:
    Ting Wang
    ,
    Jobaidur R. Khan
    DOI: 10.1115/1.4002755
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A stage-by-stage wet compression theory and algorithm have been developed for overspray and interstage fogging in the compressor. These theory and algorithm are used to calculate the performance of an eight-stage compressor under both dry and wet compressions. A 2D compressor airfoil geometry and stage setting at the mean radius are employed. Six different cases with and without overspray are investigated and compared. The stage pressure ratio enhances during all fogging cases as does the overall pressure ratio, with saturated fogging (no overspray) achieving the highest pressure ratio. Saturated fogging reduces specific compressor work, but increases the total compressor power due to increased mass flow rate. The results of overspray and interstage spray unexpectedly show that both the specific and overall compressor power do not reduce but actually increase. Analysis shows that this increased power is contributed by the increased pressure ratio and, for interstage overspray, “recompression” contributes to more power consumption. Also it is unexpected to see that air density actually decreases, instead of increases, inside the compressor with overspray. Analysis shows that overspray induces an excessive reduction in temperature that leads to an appreciable reduction in pressure, so the increment of density due to reduced temperature is less than the decrement of air density affected by reduced pressure as air follows the polytropic relationship. In contrast, saturated fogging results in increased density as expected. After the interstage spray, the local blade loading immediately showed a significant increase. Fogging increases axial velocity, flow coefficient, blade inlet velocity, incidence angle, and tangential component of velocity. The analysis also assesses the use of an average shape factor in the generalized compressor stage performance curve when the compressor stage information and performance map are not available. The result indicates that using a constant shape factor might not be adequate because the compressor performance map may have changed with wet compression. The results of nonstage-stacking simulation are shown to underpredict the compressor power by about 6% and the net gas turbine output by about 2% in the studied cases.
    keyword(s): Pressure , Compressors , Gas turbines , Flow (Dynamics) , Temperature , Cooling , Compression , Water AND Sprays ,
    • Download: (2.007Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Overspray and Interstage Fog Cooling in Gas Turbine Compressor Using Stage-Stacking Scheme—Part II: Case Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/144824
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorTing Wang
    contributor authorJobaidur R. Khan
    date accessioned2017-05-09T00:40:53Z
    date available2017-05-09T00:40:53Z
    date copyrightSeptember, 2010
    date issued2010
    identifier issn1948-5085
    identifier otherJTSEBV-28819#031002_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/144824
    description abstractA stage-by-stage wet compression theory and algorithm have been developed for overspray and interstage fogging in the compressor. These theory and algorithm are used to calculate the performance of an eight-stage compressor under both dry and wet compressions. A 2D compressor airfoil geometry and stage setting at the mean radius are employed. Six different cases with and without overspray are investigated and compared. The stage pressure ratio enhances during all fogging cases as does the overall pressure ratio, with saturated fogging (no overspray) achieving the highest pressure ratio. Saturated fogging reduces specific compressor work, but increases the total compressor power due to increased mass flow rate. The results of overspray and interstage spray unexpectedly show that both the specific and overall compressor power do not reduce but actually increase. Analysis shows that this increased power is contributed by the increased pressure ratio and, for interstage overspray, “recompression” contributes to more power consumption. Also it is unexpected to see that air density actually decreases, instead of increases, inside the compressor with overspray. Analysis shows that overspray induces an excessive reduction in temperature that leads to an appreciable reduction in pressure, so the increment of density due to reduced temperature is less than the decrement of air density affected by reduced pressure as air follows the polytropic relationship. In contrast, saturated fogging results in increased density as expected. After the interstage spray, the local blade loading immediately showed a significant increase. Fogging increases axial velocity, flow coefficient, blade inlet velocity, incidence angle, and tangential component of velocity. The analysis also assesses the use of an average shape factor in the generalized compressor stage performance curve when the compressor stage information and performance map are not available. The result indicates that using a constant shape factor might not be adequate because the compressor performance map may have changed with wet compression. The results of nonstage-stacking simulation are shown to underpredict the compressor power by about 6% and the net gas turbine output by about 2% in the studied cases.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleOverspray and Interstage Fog Cooling in Gas Turbine Compressor Using Stage-Stacking Scheme—Part II: Case Study
    typeJournal Paper
    journal volume2
    journal issue3
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4002755
    journal fristpage31002
    identifier eissn1948-5093
    keywordsPressure
    keywordsCompressors
    keywordsGas turbines
    keywordsFlow (Dynamics)
    keywordsTemperature
    keywordsCooling
    keywordsCompression
    keywordsWater AND Sprays
    treeJournal of Thermal Science and Engineering Applications:;2010:;volume( 002 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian