Show simple item record

contributor authorTing Wang
contributor authorJobaidur R. Khan
date accessioned2017-05-09T00:40:53Z
date available2017-05-09T00:40:53Z
date copyrightSeptember, 2010
date issued2010
identifier issn1948-5085
identifier otherJTSEBV-28819#031002_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/144824
description abstractA stage-by-stage wet compression theory and algorithm have been developed for overspray and interstage fogging in the compressor. These theory and algorithm are used to calculate the performance of an eight-stage compressor under both dry and wet compressions. A 2D compressor airfoil geometry and stage setting at the mean radius are employed. Six different cases with and without overspray are investigated and compared. The stage pressure ratio enhances during all fogging cases as does the overall pressure ratio, with saturated fogging (no overspray) achieving the highest pressure ratio. Saturated fogging reduces specific compressor work, but increases the total compressor power due to increased mass flow rate. The results of overspray and interstage spray unexpectedly show that both the specific and overall compressor power do not reduce but actually increase. Analysis shows that this increased power is contributed by the increased pressure ratio and, for interstage overspray, “recompression” contributes to more power consumption. Also it is unexpected to see that air density actually decreases, instead of increases, inside the compressor with overspray. Analysis shows that overspray induces an excessive reduction in temperature that leads to an appreciable reduction in pressure, so the increment of density due to reduced temperature is less than the decrement of air density affected by reduced pressure as air follows the polytropic relationship. In contrast, saturated fogging results in increased density as expected. After the interstage spray, the local blade loading immediately showed a significant increase. Fogging increases axial velocity, flow coefficient, blade inlet velocity, incidence angle, and tangential component of velocity. The analysis also assesses the use of an average shape factor in the generalized compressor stage performance curve when the compressor stage information and performance map are not available. The result indicates that using a constant shape factor might not be adequate because the compressor performance map may have changed with wet compression. The results of nonstage-stacking simulation are shown to underpredict the compressor power by about 6% and the net gas turbine output by about 2% in the studied cases.
publisherThe American Society of Mechanical Engineers (ASME)
titleOverspray and Interstage Fog Cooling in Gas Turbine Compressor Using Stage-Stacking Scheme—Part II: Case Study
typeJournal Paper
journal volume2
journal issue3
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4002755
journal fristpage31002
identifier eissn1948-5093
keywordsPressure
keywordsCompressors
keywordsGas turbines
keywordsFlow (Dynamics)
keywordsTemperature
keywordsCooling
keywordsCompression
keywordsWater AND Sprays
treeJournal of Thermal Science and Engineering Applications:;2010:;volume( 002 ):;issue: 003