    Efficient Operation of Air-Side Economizer Using Extremum Seeking Control

    Source: Journal of Dynamic Systems, Measurement, and Control:;2010:;volume( 132 ):;issue: 003::page 31009
    Author:
    Pengfei Li
    ,
    John E. Seem
    ,
    Yaoyu Li
    DOI: 10.1115/1.4001216
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: As the heating, ventilating, and air conditioning (HVAC) systems accounts for a major sector of energy consumption for commercial buildings, there has been a greater demand for improving the efficiency of such systems. The air-side economizers have been developed as a class of energy-saving HVAC devices that may increase the energy efficiency by taking advantage of outdoor air during cool or cold weather. However, many economizers do not operate in the expected manner and waste even more energy than before installation, mostly due to the unreliable sensors and actuators in practice. Better control strategy is needed for optimal and robust operation. In this paper, an extremum-seeking control (ESC) based self-optimizing strategy is proposed to minimize the energy consumption, with the feedback of chilled water supply command rather than the temperature and humidity measurements. The mechanical cooling load is minimized by seeking the optimal outdoor air damper opening in real time. Such scheme does not need temperature and humidity sensors, and depends much less on the knowledge of the economizer model. Simulation was performed on a MODELICA based transient model of a single-duct air-handling unit developed with DYMOLA and AIRCONDITIONING LIBRARY . The simulation results demonstrated the potential of using ESC to achieve the minimal mechanical cooling load in a self-optimizing manner. In addition, an antiwindup ESC scheme is proposed to handle the ESC windup issue due to actuator (damper) saturation. The simulation results validated the effectiveness of the proposed antiwindup ESC.
    • Download: (1.176Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Efficient Operation of Air-Side Economizer Using Extremum Seeking Control

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/142874
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorPengfei Li
    contributor authorJohn E. Seem
    contributor authorYaoyu Li
    date accessioned2017-05-09T00:37:07Z
    date available2017-05-09T00:37:07Z
    date copyrightMay, 2010
    date issued2010
    identifier issn0022-0434
    identifier otherJDSMAA-26520#031009_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142874
    description abstractAs the heating, ventilating, and air conditioning (HVAC) systems accounts for a major sector of energy consumption for commercial buildings, there has been a greater demand for improving the efficiency of such systems. The air-side economizers have been developed as a class of energy-saving HVAC devices that may increase the energy efficiency by taking advantage of outdoor air during cool or cold weather. However, many economizers do not operate in the expected manner and waste even more energy than before installation, mostly due to the unreliable sensors and actuators in practice. Better control strategy is needed for optimal and robust operation. In this paper, an extremum-seeking control (ESC) based self-optimizing strategy is proposed to minimize the energy consumption, with the feedback of chilled water supply command rather than the temperature and humidity measurements. The mechanical cooling load is minimized by seeking the optimal outdoor air damper opening in real time. Such scheme does not need temperature and humidity sensors, and depends much less on the knowledge of the economizer model. Simulation was performed on a MODELICA based transient model of a single-duct air-handling unit developed with DYMOLA and AIRCONDITIONING LIBRARY . The simulation results demonstrated the potential of using ESC to achieve the minimal mechanical cooling load in a self-optimizing manner. In addition, an antiwindup ESC scheme is proposed to handle the ESC windup issue due to actuator (damper) saturation. The simulation results validated the effectiveness of the proposed antiwindup ESC.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEfficient Operation of Air-Side Economizer Using Extremum Seeking Control
    typeJournal Paper
    journal volume132
    journal issue3
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.4001216
    journal fristpage31009
    identifier eissn1528-9028
    treeJournal of Dynamic Systems, Measurement, and Control:;2010:;volume( 132 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian