    Behavior of Anisotropic Conductive Film (ACF) Joint under Mechanical Shock

    Source: Journal of Electronic Packaging:;2005:;volume( 127 ):;issue: 004::page 375
    Author:
    Rashed Adnan Islam
    ,
    Y. C. Chan
    DOI: 10.1115/1.2056570
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The contact resistances investigated by this study of ACF joints using Au∕Ni bumps and flexible substrates are found to be increased by the induced mechanical shock and also by the combined effect of heat/humidity and the mechanical shock. The samples humidified at 85°C/85% RH for 384 h, on which a load of 3.164 Kg was dropped four times from a height of 0.4 m, exhibit the most severe results. The contact resistance increases by 700%, which had been about 62 mΩ in the as-bonded condition. The samples without humidification showed a sluggish and gentle increase in contact resistance with the induced mechanical shock. The contact resistance was found to be increased by 400% after the sixth drop from a height of 0.5 m. Scanning electron microscope images show particle deformation due to abrasion and friction between the contacting surfaces resulting from the sudden impact. Joints are also observed with no connections, which signify open circuits. Almost 25% of the circuits were found open in the samples (after 384 h in a humid environment), which have suffered severe mechanical shock (load drops four times from 0.4 m height). Breaking of the conductive layer of the particle and exposing the underlying polymeric portion were also observed.
    keyword(s): Drops , Shock (Mechanics) , Contact resistance AND Particulate matter ,
    • Download: (444.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Behavior of Anisotropic Conductive Film (ACF) Joint under Mechanical Shock

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/131597
    Collections
    • Journal of Electronic Packaging

    Show full item record

    contributor authorRashed Adnan Islam
    contributor authorY. C. Chan
    date accessioned2017-05-09T00:15:49Z
    date available2017-05-09T00:15:49Z
    date copyrightDecember, 2005
    date issued2005
    identifier issn1528-9044
    identifier otherJEPAE4-26254#375_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/131597
    description abstractThe contact resistances investigated by this study of ACF joints using Au∕Ni bumps and flexible substrates are found to be increased by the induced mechanical shock and also by the combined effect of heat/humidity and the mechanical shock. The samples humidified at 85°C/85% RH for 384 h, on which a load of 3.164 Kg was dropped four times from a height of 0.4 m, exhibit the most severe results. The contact resistance increases by 700%, which had been about 62 mΩ in the as-bonded condition. The samples without humidification showed a sluggish and gentle increase in contact resistance with the induced mechanical shock. The contact resistance was found to be increased by 400% after the sixth drop from a height of 0.5 m. Scanning electron microscope images show particle deformation due to abrasion and friction between the contacting surfaces resulting from the sudden impact. Joints are also observed with no connections, which signify open circuits. Almost 25% of the circuits were found open in the samples (after 384 h in a humid environment), which have suffered severe mechanical shock (load drops four times from 0.4 m height). Breaking of the conductive layer of the particle and exposing the underlying polymeric portion were also observed.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleBehavior of Anisotropic Conductive Film (ACF) Joint under Mechanical Shock
    typeJournal Paper
    journal volume127
    journal issue4
    journal titleJournal of Electronic Packaging
    identifier doi10.1115/1.2056570
    journal fristpage375
    journal lastpage380
    identifier eissn1043-7398
    keywordsDrops
    keywordsShock (Mechanics)
    keywordsContact resistance AND Particulate matter
    treeJournal of Electronic Packaging:;2005:;volume( 127 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian