    Mixed Convection of Impinging Air Cooling Over Heat Sink in Telecom System Application

    Source: Journal of Electronic Packaging:;2004:;volume( 126 ):;issue: 004::page 519
    Author:
    Siddharth Bhopte
    ,
    Gamal Refai-Ahmed
    ,
    Musa S. Alshuqairi
    ,
    Dereje Agonafer
    DOI: 10.1115/1.1827267
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The current numerical investigation will examine the effect of an impinging mixed convection air jet on the heat transfer rate of a parallel flat plate heat sink. A three-dimensional numerical model was developed to evaluate the effects of the nozzle diameter d, nozzle-to-target vertical placement H/d, Rayleigh number, and the jet Reynolds number on the heat transfer rates from a discrete heat source. Simulations were performed for a Prandtl number of 0.7 and for Reynolds numbers ranging from 100 to 5000. The governing equations were solved in the dimensionless form using a commercial finite-volume package. Average Nusselt numbers were obtained, at H/d=3 and two jet diameters, for the bare heat source, for the heat source with a base heat sink, and for the heat source with the finned heat sink. The heat transfer rates from the bare heat source surface have been compared with the ones obtained with the heat sink in order to determine the overall performance of the heat sink in an impingement configuration.
    keyword(s): Flow (Dynamics) , Heat , Computer simulation , Mixed convection , Heat sinks , Cooling , Heat transfer , Reynolds number , Natural convection , Rayleigh number AND Temperature ,
    • Download: (973.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Mixed Convection of Impinging Air Cooling Over Heat Sink in Telecom System Application

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/129836
    Collections
    • Journal of Electronic Packaging

    Show full item record

    contributor authorSiddharth Bhopte
    contributor authorGamal Refai-Ahmed
    contributor authorMusa S. Alshuqairi
    contributor authorDereje Agonafer
    date accessioned2017-05-09T00:12:41Z
    date available2017-05-09T00:12:41Z
    date copyrightDecember, 2004
    date issued2004
    identifier issn1528-9044
    identifier otherJEPAE4-26239#519_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/129836
    description abstractThe current numerical investigation will examine the effect of an impinging mixed convection air jet on the heat transfer rate of a parallel flat plate heat sink. A three-dimensional numerical model was developed to evaluate the effects of the nozzle diameter d, nozzle-to-target vertical placement H/d, Rayleigh number, and the jet Reynolds number on the heat transfer rates from a discrete heat source. Simulations were performed for a Prandtl number of 0.7 and for Reynolds numbers ranging from 100 to 5000. The governing equations were solved in the dimensionless form using a commercial finite-volume package. Average Nusselt numbers were obtained, at H/d=3 and two jet diameters, for the bare heat source, for the heat source with a base heat sink, and for the heat source with the finned heat sink. The heat transfer rates from the bare heat source surface have been compared with the ones obtained with the heat sink in order to determine the overall performance of the heat sink in an impingement configuration.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMixed Convection of Impinging Air Cooling Over Heat Sink in Telecom System Application
    typeJournal Paper
    journal volume126
    journal issue4
    journal titleJournal of Electronic Packaging
    identifier doi10.1115/1.1827267
    journal fristpage519
    journal lastpage523
    identifier eissn1043-7398
    keywordsFlow (Dynamics)
    keywordsHeat
    keywordsComputer simulation
    keywordsMixed convection
    keywordsHeat sinks
    keywordsCooling
    keywordsHeat transfer
    keywordsReynolds number
    keywordsNatural convection
    keywordsRayleigh number AND Temperature
    treeJournal of Electronic Packaging:;2004:;volume( 126 ):;issue: 004
    contenttypeFulltext