    Natural Convection Air Cooling of a Discrete Heat Source on a Conducting Board in a Shallow Horizontal Enclosure

    Source: Journal of Electronic Packaging:;1998:;volume( 120 ):;issue: 001::page 89
    Author:
    A. Ortega
    ,
    B. S. Lall
    DOI: 10.1115/1.2792291
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Experiments were performed to measure the heat transfer coefficient on the surface of a square flush heat source mounted at the center of an FR-4 plate in a small horizontal enclosure. The plate area was six times larger than the heat source area. Four cases were considered: the plate facing upwards and downwards, and the backside either insulated or convecting. The heat transfer coefficients exhibited distinct behavior at high aspect ratio in which the dominant length scales were related to the source. At intermediate aspect ratios, the length scales of both the source and the enclosure were relevant, and at small aspect ratios a conduction limit was observed. The heat transfer coefficients at high aspect ratios exceeded the prior correlations by 14 percent for upward facing isolated plates when the ratio of heat source area to perimeter was used as the significant length scale, but the dependence on Ra1/4 was consistent. For the downward facing case, the data exceeded the values for a uniformly heated isolated plate by 68 percent. Classical correlations for shallow differentially heated horizontal enclosures were not satisfactory in describing the dependence on enclosure height.
    keyword(s): Heat , Cooling , Natural convection , Foundry coatings , Heat transfer coefficients , Plates (structures) AND Heat conduction ,
    • Download: (992.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Natural Convection Air Cooling of a Discrete Heat Source on a Conducting Board in a Shallow Horizontal Enclosure

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/120294
    Collections
    • Journal of Electronic Packaging

    Show full item record

    contributor authorA. Ortega
    contributor authorB. S. Lall
    date accessioned2017-05-08T23:56:20Z
    date available2017-05-08T23:56:20Z
    date copyrightMarch, 1998
    date issued1998
    identifier issn1528-9044
    identifier otherJEPAE4-26165#89_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/120294
    description abstractExperiments were performed to measure the heat transfer coefficient on the surface of a square flush heat source mounted at the center of an FR-4 plate in a small horizontal enclosure. The plate area was six times larger than the heat source area. Four cases were considered: the plate facing upwards and downwards, and the backside either insulated or convecting. The heat transfer coefficients exhibited distinct behavior at high aspect ratio in which the dominant length scales were related to the source. At intermediate aspect ratios, the length scales of both the source and the enclosure were relevant, and at small aspect ratios a conduction limit was observed. The heat transfer coefficients at high aspect ratios exceeded the prior correlations by 14 percent for upward facing isolated plates when the ratio of heat source area to perimeter was used as the significant length scale, but the dependence on Ra1/4 was consistent. For the downward facing case, the data exceeded the values for a uniformly heated isolated plate by 68 percent. Classical correlations for shallow differentially heated horizontal enclosures were not satisfactory in describing the dependence on enclosure height.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNatural Convection Air Cooling of a Discrete Heat Source on a Conducting Board in a Shallow Horizontal Enclosure
    typeJournal Paper
    journal volume120
    journal issue1
    journal titleJournal of Electronic Packaging
    identifier doi10.1115/1.2792291
    journal fristpage89
    journal lastpage97
    identifier eissn1043-7398
    keywordsHeat
    keywordsCooling
    keywordsNatural convection
    keywordsFoundry coatings
    keywordsHeat transfer coefficients
    keywordsPlates (structures) AND Heat conduction
    treeJournal of Electronic Packaging:;1998:;volume( 120 ):;issue: 001
    contenttypeFulltext