| contributor author | S. S. Garimella | |
| contributor author | K. Srinivasan | |
| date accessioned | 2017-05-08T23:49:31Z | |
| date available | 2017-05-08T23:49:31Z | |
| date copyright | December, 1996 | |
| date issued | 1996 | |
| identifier issn | 0022-0434 | |
| identifier other | JDSMAA-26230#795_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/116616 | |
| description abstract | Upper bounds on transient response magnitudes for a SISO continuous-time repetitive control system are derived. Limiting the size of these transients is shown to be related to limiting the ∞-norm of a transfer function product of filters used in the repetitive controller. The decay rate of the transients is related to the peak of a function of frequency called the regeneration spectrum, which has previously been shown in the literature to be a measure of the relative stability of the system. Bounds derived here, although conservative, can be useful in the design of the repetitive controller, as illustrated by means of an example. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Transient Response of Repetitive Control Systems | |
| type | Journal Paper | |
| journal volume | 118 | |
| journal issue | 4 | |
| journal title | Journal of Dynamic Systems, Measurement, and Control | |
| identifier doi | 10.1115/1.2802360 | |
| journal fristpage | 795 | |
| journal lastpage | 797 | |
| identifier eissn | 1528-9028 | |
| tree | Journal of Dynamic Systems, Measurement, and Control:;1996:;volume( 118 ):;issue: 004 | |
| contenttype | Fulltext | |