Reliable Ceramic Window Design for Electronic DevicesSource: Journal of Electronic Packaging:;1992:;volume( 114 ):;issue: 003::page 349Author:Hsien-Yang Yeh
DOI: 10.1115/1.2905462Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The effective operations of a high voltage vacuum electronic device, such as a traveling wave tube, depends on its ability to maintain high vacuum environments. However, during temperature tests, some tubes fail because of vacuum leaks through cracks in the ceramic window. It is believed that these leaks result from RF heating at the center conductor, which caused the ceramic to crack. To obtain a general understanding of the stress field in the window structure, a closed from analytical approach is imperative. However, due to the complex nature of the problem, only the first order engineering approximation is used in this preliminary study. The theory of linear elastic fracture mechanics and the existing solutions from elastic circular plates are useful for understanding the cause of ceramic window cracks. Some simple design references have also been developed for the design of reliable ceramic windows for traveling wave tubes.
keyword(s): Ceramics , Design , Fracture (Materials) , Vacuum , Waves , Travel , Leakage , Heating , Plates (structures) , Approximation , Stress , Fracture mechanics , Temperature AND Electric potential ,
|
Collections
Show full item record
contributor author | Hsien-Yang Yeh | |
date accessioned | 2017-05-08T23:38:06Z | |
date available | 2017-05-08T23:38:06Z | |
date copyright | September, 1992 | |
date issued | 1992 | |
identifier issn | 1528-9044 | |
identifier other | JEPAE4-26132#349_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/110054 | |
description abstract | The effective operations of a high voltage vacuum electronic device, such as a traveling wave tube, depends on its ability to maintain high vacuum environments. However, during temperature tests, some tubes fail because of vacuum leaks through cracks in the ceramic window. It is believed that these leaks result from RF heating at the center conductor, which caused the ceramic to crack. To obtain a general understanding of the stress field in the window structure, a closed from analytical approach is imperative. However, due to the complex nature of the problem, only the first order engineering approximation is used in this preliminary study. The theory of linear elastic fracture mechanics and the existing solutions from elastic circular plates are useful for understanding the cause of ceramic window cracks. Some simple design references have also been developed for the design of reliable ceramic windows for traveling wave tubes. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Reliable Ceramic Window Design for Electronic Devices | |
type | Journal Paper | |
journal volume | 114 | |
journal issue | 3 | |
journal title | Journal of Electronic Packaging | |
identifier doi | 10.1115/1.2905462 | |
journal fristpage | 349 | |
journal lastpage | 352 | |
identifier eissn | 1043-7398 | |
keywords | Ceramics | |
keywords | Design | |
keywords | Fracture (Materials) | |
keywords | Vacuum | |
keywords | Waves | |
keywords | Travel | |
keywords | Leakage | |
keywords | Heating | |
keywords | Plates (structures) | |
keywords | Approximation | |
keywords | Stress | |
keywords | Fracture mechanics | |
keywords | Temperature AND Electric potential | |
tree | Journal of Electronic Packaging:;1992:;volume( 114 ):;issue: 003 | |
contenttype | Fulltext |