Show simple item record

contributor authorM. S. Yuki
contributor authorJ. R. Parsons
contributor authorR. J. Krane
date accessioned2017-05-08T23:32:19Z
date available2017-05-08T23:32:19Z
date copyrightDecember, 1990
date issued1990
identifier issn1528-9044
identifier otherJEPAE4-26119#279_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/106740
description abstractEconomic and reliability considerations lead to the adoption of passive techniques for cooling by a combination of natural convection and radiation heat transfer. In order to facilitate the cooling by natural convection, thermal design engineers commonly incorporate vent openings in the walls of a receiver cabinet. Unfortunately, natural convection flows in complex, vented enclosures are presently not well understood and designers must employ “cut and try” methodologies to determine the sizes and locations of vent openings. Since vent openings are expensive to incorporate in consumer electronic products, it was decided to develop the techniques that would enable thermal designers to minimize the number of vent openings in a TV cabinet and maximize the effectiveness of those vents that are employed. Thus, the present study represents the first step in a rational program to develop the tools that will enable engineers to optimize the thermal design of a table model television receiver. In this initial work, experiments were performed to determine the effects of vent size and location on component cooling in a representative table model receiver. Vents were systematically blocked until the set was operated in a completely sealed condition. Measurements of component, air, and cabinet wall temperatures and the results of flow visualization experiments were used to assess the effects of various combinations of vent openings on the natural convection cooling of the receiver. Results indicate that: (1) the present design of the vent system of a representative, commercially available table model television receiver is adequate, but has not been optimized, and (2) significant improvements in the design of the vent could be achieved; that is, improved component cooling could be obtained with fewer vent openings. The results of this work, which should be directly applicable by thermal designers, will also serve to experimentally verify numerical models of the natural convection flows through television receivers that are currently under development.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn Investigation of the Passive Cooling of Table Model Television Receivers
typeJournal Paper
journal volume112
journal issue4
journal titleJournal of Electronic Packaging
identifier doi10.1115/1.2904380
journal fristpage279
journal lastpage287
identifier eissn1043-7398
keywordsCooling
treeJournal of Electronic Packaging:;1990:;volume( 112 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record