    Off-Design Exergy Audit of a Thermal Power Station

    Source: Journal of Engineering for Gas Turbines and Power:;1988:;volume( 110 ):;issue: 002::page 166
    Author:
    E. Yasni
    ,
    C. G. Carrington
    DOI: 10.1115/1.3240096
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A second-law state analysis procedure, having on-line capability, has been implemented at a fossil-fueled power station at Huntly, N.Z. The analysis fully integrates the combustion and steam processes in order to provide a viable understanding of the influence of operating parameters on the distribution of losses within the plant. The procedures do not rely significantly on manufacturer’s performance data and the validity of the audit is substantially verifiable. Examples of audit data are presented, including operation with and without the top heater and a comparison of throttle and sliding pressure control.
    keyword(s): Combustion , Exergy , Design , Power stations , Industrial plants , Pressure control , Steam AND Thermal power stations ,
    • Download: (829.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Off-Design Exergy Audit of a Thermal Power Station

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/103884
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorE. Yasni
    contributor authorC. G. Carrington
    date accessioned2017-05-08T23:27:08Z
    date available2017-05-08T23:27:08Z
    date copyrightApril, 1988
    date issued1988
    identifier issn1528-8919
    identifier otherJETPEZ-26654#166_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/103884
    description abstractA second-law state analysis procedure, having on-line capability, has been implemented at a fossil-fueled power station at Huntly, N.Z. The analysis fully integrates the combustion and steam processes in order to provide a viable understanding of the influence of operating parameters on the distribution of losses within the plant. The procedures do not rely significantly on manufacturer’s performance data and the validity of the audit is substantially verifiable. Examples of audit data are presented, including operation with and without the top heater and a comparison of throttle and sliding pressure control.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleOff-Design Exergy Audit of a Thermal Power Station
    typeJournal Paper
    journal volume110
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.3240096
    journal fristpage166
    journal lastpage172
    identifier eissn0742-4795
    keywordsCombustion
    keywordsExergy
    keywordsDesign
    keywordsPower stations
    keywordsIndustrial plants
    keywordsPressure control
    keywordsSteam AND Thermal power stations
    treeJournal of Engineering for Gas Turbines and Power:;1988:;volume( 110 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian