description abstractA second-law state analysis procedure, having on-line capability, has been implemented at a fossil-fueled power station at Huntly, N.Z. The analysis fully integrates the combustion and steam processes in order to provide a viable understanding of the influence of operating parameters on the distribution of losses within the plant. The procedures do not rely significantly on manufacturer’s performance data and the validity of the audit is substantially verifiable. Examples of audit data are presented, including operation with and without the top heater and a comparison of throttle and sliding pressure control.
publisherThe American Society of Mechanical Engineers (ASME)
titleOff-Design Exergy Audit of a Thermal Power Station
typeJournal Paper
journal volume110
journal issue2
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.3240096
journal fristpage166
journal lastpage172
identifier eissn0742-4795
keywordsCombustion
keywordsExergy
keywordsDesign
keywordsPower stations
keywordsIndustrial plants
keywordsPressure control
keywordsSteam AND Thermal power stations
treeJournal of Engineering for Gas Turbines and Power:;1988:;volume( 110 ):;issue: 002