contributor author | B. S. Johnston | |
contributor author | A. Sharon | |
contributor author | Y. Kozawa | |
contributor author | S. G. Bankoff | |
date accessioned | 2017-05-08T23:15:21Z | |
date available | 2017-05-08T23:15:21Z | |
date copyright | October, 1983 | |
date issued | 1983 | |
identifier issn | 1528-8919 | |
identifier other | JETPEZ-26784#742_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/97008 | |
description abstract | An experimental apparatus was used to simulate the annular crevice formed by a heated tube and drilled tube support plate (TSP) in a pressurized water reactor recirculating steam generator. The aim of the experiment was to explore the conditions required for the formation and maintenance of a dry region. Water at 0.69 MPa or atmospheric pressure was circulated through the crevice. Visual observations and tube wall temperature measurements were obtained and compared to synthesize a description of the crevice boiling processes. It was determiend that a stable dry patch exists about a line of contact between tube and TSP above a wall superheat of 2–3°C. However, separating the tube and TSP by about 0.025 mm allows the dry patch to be rewet. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Boiling Heat Transfer in a Narrow Eccentric Annulus, Part I: Dryout | |
type | Journal Paper | |
journal volume | 105 | |
journal issue | 4 | |
journal title | Journal of Engineering for Gas Turbines and Power | |
identifier doi | 10.1115/1.3227476 | |
journal fristpage | 742 | |
journal lastpage | 747 | |
identifier eissn | 0742-4795 | |
keywords | Heat transfer | |
keywords | Boiling | |
keywords | Annulus | |
keywords | Wall temperature | |
keywords | Water | |
keywords | Pressurized water reactors | |
keywords | Atmospheric pressure | |
keywords | Measurement | |
keywords | Maintenance AND Boilers | |
tree | Journal of Engineering for Gas Turbines and Power:;1983:;volume( 105 ):;issue: 004 | |
contenttype | Fulltext | |