Study of Bolted Joint Integrity and Inter-Tube-Pass Leakage in U-Tube Heat Exchangers—Part I: AnalysisSource: Journal of Engineering for Gas Turbines and Power:;1979:;volume( 101 ):;issue: 001::page 9Author:K. P. Singh
DOI: 10.1115/1.3446470Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: “Three element bolted joints,” consisting of an unstayed tubesheet sandwiched between two tapered hub flanges, find extensive use in U-tube type heat exchangers. A comprehensive analysis technique is herein developed to investigate the structural characteristics of such joints. Design strategies to reduce stress levels in the tubesheet and the flanges are proposed. In particular, the concept of “controlled” metal-to-metal contact beyond the bolt circle between the mating surfaces is introduced and explored in depth. The solution is readily programmed on a digital computer for application in analysis oriented design evaluation and optimization studies.
keyword(s): Heat exchangers , Leakage , Metals , Flanges , Design , Stress , Bolted joints , Optimization AND Computers ,
|
Show full item record
| contributor author | K. P. Singh | |
| date accessioned | 2017-05-08T23:06:46Z | |
| date available | 2017-05-08T23:06:46Z | |
| date copyright | January, 1979 | |
| date issued | 1979 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-26746#9_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/92140 | |
| description abstract | “Three element bolted joints,” consisting of an unstayed tubesheet sandwiched between two tapered hub flanges, find extensive use in U-tube type heat exchangers. A comprehensive analysis technique is herein developed to investigate the structural characteristics of such joints. Design strategies to reduce stress levels in the tubesheet and the flanges are proposed. In particular, the concept of “controlled” metal-to-metal contact beyond the bolt circle between the mating surfaces is introduced and explored in depth. The solution is readily programmed on a digital computer for application in analysis oriented design evaluation and optimization studies. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Study of Bolted Joint Integrity and Inter-Tube-Pass Leakage in U-Tube Heat Exchangers—Part I: Analysis | |
| type | Journal Paper | |
| journal volume | 101 | |
| journal issue | 1 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.3446470 | |
| journal fristpage | 9 | |
| journal lastpage | 15 | |
| identifier eissn | 0742-4795 | |
| keywords | Heat exchangers | |
| keywords | Leakage | |
| keywords | Metals | |
| keywords | Flanges | |
| keywords | Design | |
| keywords | Stress | |
| keywords | Bolted joints | |
| keywords | Optimization AND Computers | |
| tree | Journal of Engineering for Gas Turbines and Power:;1979:;volume( 101 ):;issue: 001 | |
| contenttype | Fulltext |