| contributor author | Mauricio Angulo | |
| contributor author | Wilson H. Tang | |
| date accessioned | 2017-05-08T21:26:44Z | |
| date available | 2017-05-08T21:26:44Z | |
| date copyright | June 1999 | |
| date issued | 1999 | |
| identifier other | %28asce%291090-0241%281999%29125%3A6%28510%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/51736 | |
| description abstract | Ground-water detection monitoring decisions are complicated due to uncertainties in contaminant source characteristics and inherent variability of hydrogeologic conditions. The desire to meet multiple monitoring objectives presents an additional challenge. A novel approach using probability tools is presented to optimally determine the number and location of monitoring wells that compose a system for detection monitoring purposes. | |
| publisher | American Society of Civil Engineers | |
| title | Optimal Ground-Water Detection Monitoring System Design under Uncertainty | |
| type | Journal Paper | |
| journal volume | 125 | |
| journal issue | 6 | |
| journal title | Journal of Geotechnical and Geoenvironmental Engineering | |
| identifier doi | 10.1061/(ASCE)1090-0241(1999)125:6(510) | |
| tree | Journal of Geotechnical and Geoenvironmental Engineering:;1999:;Volume ( 125 ):;issue: 006 | |
| contenttype | Fulltext | |