Experimental Performance Analysis of Solar Air Heater With Innovative Perforated Semi-Conical RibsSource: Journal of Solar Energy Engineering:;2025:;volume( 147 ):;issue: 003::page 31008-1DOI: 10.1115/1.4067372Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This study investigates the performance of two solar air heater designs, S1-SAH and S2-SAH, through experimental analysis of temperature, energy gain and loss, efficiency, and Thermal-Hydraulic Performance Parameter (THPP) across mass flow rates ranging from 0.013 to 0.061 kg/s in hot climatic conditions of R.E.C Banda. The S2-SAH consistently outperformed the conventional S1-SAH, achieving a maximum energy efficiency of 79.3% at 0.051 kg/s and a peak exergy efficiency of 4.5% at 0.013 kg/s. Additionally, the highest THPP of 2.0 was recorded at 0.051 kg/s. The results highlight the superior performance and enhanced efficiency of the S2-SAH, showcasing the effectiveness of its design for improved heat transfer.
|
Collections
Show full item record
contributor author | Shankar, Ravi | |
contributor author | Kumar, Rajeev | |
contributor author | Pandey, Arun Kumar | |
contributor author | Thakur, Deep Singh | |
date accessioned | 2025-04-21T10:33:54Z | |
date available | 2025-04-21T10:33:54Z | |
date copyright | 1/2/2025 12:00:00 AM | |
date issued | 2025 | |
identifier issn | 0199-6231 | |
identifier other | sol_147_3_031008.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4306452 | |
description abstract | This study investigates the performance of two solar air heater designs, S1-SAH and S2-SAH, through experimental analysis of temperature, energy gain and loss, efficiency, and Thermal-Hydraulic Performance Parameter (THPP) across mass flow rates ranging from 0.013 to 0.061 kg/s in hot climatic conditions of R.E.C Banda. The S2-SAH consistently outperformed the conventional S1-SAH, achieving a maximum energy efficiency of 79.3% at 0.051 kg/s and a peak exergy efficiency of 4.5% at 0.013 kg/s. Additionally, the highest THPP of 2.0 was recorded at 0.051 kg/s. The results highlight the superior performance and enhanced efficiency of the S2-SAH, showcasing the effectiveness of its design for improved heat transfer. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Experimental Performance Analysis of Solar Air Heater With Innovative Perforated Semi-Conical Ribs | |
type | Journal Paper | |
journal volume | 147 | |
journal issue | 3 | |
journal title | Journal of Solar Energy Engineering | |
identifier doi | 10.1115/1.4067372 | |
journal fristpage | 31008-1 | |
journal lastpage | 31008-11 | |
page | 11 | |
tree | Journal of Solar Energy Engineering:;2025:;volume( 147 ):;issue: 003 | |
contenttype | Fulltext |