    Speed Strategy on High-Pressure Compressor for the Charging Process of Advanced Adiabatic Compressed Air Energy Storage During Dynamic Shutdown

    Source: Journal of Engineering for Gas Turbines and Power:;2024:;volume( 147 ):;issue: 001::page 11022-1
    Author:
    Wang, Yi
    ,
    Qin, Guoliang
    ,
    Jia, Cheng
    ,
    Cui, Qin
    DOI: 10.1115/1.4066358
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Advanced adiabatic compressed air energy storage (AA-CAES) starts and shuts down frequently. The default operation of the high-pressure compressor (HP) connected to the cavern is to reduce the speed of the inverter motor during shutdown. Whether or not the default speed strategy is safe has yet to be focused on. To this end, a detailed charging process comprising three series of centrifugal compressors with intercoolers was constructed within the framework of unisimdesign. The safety measures were meticulously considered by integrating antisurge circuits, vent valves, and check valves. Proportional–integral (PI) controllers were allocated to the primary component to govern the shutdown procedure. The speed strategy of the HP inverter motor during the load shedding stage is the focus of research. Six speed strategies, including decreasing speed, constant speed, and increasing speed, were discussed, respectively. The discussion focused on changes made to air injection, inlet mass flow of the HP, inlet and outlet pressure of both the middle-pressure compressor (MP) and HP, and energy efficiency. The study found that implementing the minimum allowable speed for the inverter motor speed (IMS) and increasing speed during the load shedding stage can cause fluctuations in the air injection. As IMS increases at the end of the load shedding stage, the pressure anomalies at the MP outlet and the HP inlet weaken, and the shutdown process's energy efficiency improves. The HP inlet flow fluctuations caused by various strategies were within an acceptable range. This study reveals that there is a mutual influence between components in the charging process of AA-CAES. An appropriate speed strategy for the HP inverter motor can mitigate the operational hazards. The results of this study can provide guidance for similar AA-CAES shutdowns.
    • Download: (2.829Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Speed Strategy on High-Pressure Compressor for the Charging Process of Advanced Adiabatic Compressed Air Energy Storage During Dynamic Shutdown

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305870
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorWang, Yi
    contributor authorQin, Guoliang
    contributor authorJia, Cheng
    contributor authorCui, Qin
    date accessioned2025-04-21T10:17:08Z
    date available2025-04-21T10:17:08Z
    date copyright9/27/2024 12:00:00 AM
    date issued2024
    identifier issn0742-4795
    identifier othergtp_147_01_011022.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4305870
    description abstractAdvanced adiabatic compressed air energy storage (AA-CAES) starts and shuts down frequently. The default operation of the high-pressure compressor (HP) connected to the cavern is to reduce the speed of the inverter motor during shutdown. Whether or not the default speed strategy is safe has yet to be focused on. To this end, a detailed charging process comprising three series of centrifugal compressors with intercoolers was constructed within the framework of unisimdesign. The safety measures were meticulously considered by integrating antisurge circuits, vent valves, and check valves. Proportional–integral (PI) controllers were allocated to the primary component to govern the shutdown procedure. The speed strategy of the HP inverter motor during the load shedding stage is the focus of research. Six speed strategies, including decreasing speed, constant speed, and increasing speed, were discussed, respectively. The discussion focused on changes made to air injection, inlet mass flow of the HP, inlet and outlet pressure of both the middle-pressure compressor (MP) and HP, and energy efficiency. The study found that implementing the minimum allowable speed for the inverter motor speed (IMS) and increasing speed during the load shedding stage can cause fluctuations in the air injection. As IMS increases at the end of the load shedding stage, the pressure anomalies at the MP outlet and the HP inlet weaken, and the shutdown process's energy efficiency improves. The HP inlet flow fluctuations caused by various strategies were within an acceptable range. This study reveals that there is a mutual influence between components in the charging process of AA-CAES. An appropriate speed strategy for the HP inverter motor can mitigate the operational hazards. The results of this study can provide guidance for similar AA-CAES shutdowns.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSpeed Strategy on High-Pressure Compressor for the Charging Process of Advanced Adiabatic Compressed Air Energy Storage During Dynamic Shutdown
    typeJournal Paper
    journal volume147
    journal issue1
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4066358
    journal fristpage11022-1
    journal lastpage11022-9
    page9
    treeJournal of Engineering for Gas Turbines and Power:;2024:;volume( 147 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian