    Axial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle

    Source: Journal of Engineering for Gas Turbines and Power:;2024:;volume( 147 ):;issue: 001::page 11019-1
    Author:
    Boshoff, Francois D.
    ,
    van der Spuy, Sybrand J.
    ,
    Pretorius, Johannes P.
    DOI: 10.1115/1.4066248
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: An axial flow cooling fan has been designed for use in a concentrated solar power plant. The plant is based on a supercritical carbon dioxide (sCO2) Brayton cycle, and uses a forced draft air-cooled heat exchanger (ACHE) for cooling. The fan performance has been investigated using both computational fluid dynamics (CFD) and scaled fan tests. This paper presents a CFD model that integrates the fan with the heat exchanger. The objective is to establish a foundation for similar models and to contribute to the development of efficient ACHE units designed for sCO2 power cycles. The finned-tube bundle is simplified, with a Porous Media Model representing the pressure drop through the bundle. Pressure inlet and -outlet boundary conditions are used, meaning the air flowrate is solved based on the fan and tube bundle interaction. The flowrate predicted by the CFD model is 0.5% higher than the analytical prediction, and 3.6% lower than the design value, demonstrating that the assumptions used in the design procedure are reasonable. The plenum height is also found to affect the flowrate, with shorter plenums resulting in higher flow rates and fan efficiencies, and longer plenums resulting in more uniform cooling air flow.
    • Download: (2.946Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Axial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305866
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorBoshoff, Francois D.
    contributor authorvan der Spuy, Sybrand J.
    contributor authorPretorius, Johannes P.
    date accessioned2025-04-21T10:17:01Z
    date available2025-04-21T10:17:01Z
    date copyright9/19/2024 12:00:00 AM
    date issued2024
    identifier issn0742-4795
    identifier othergtp_147_01_011019.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4305866
    description abstractAn axial flow cooling fan has been designed for use in a concentrated solar power plant. The plant is based on a supercritical carbon dioxide (sCO2) Brayton cycle, and uses a forced draft air-cooled heat exchanger (ACHE) for cooling. The fan performance has been investigated using both computational fluid dynamics (CFD) and scaled fan tests. This paper presents a CFD model that integrates the fan with the heat exchanger. The objective is to establish a foundation for similar models and to contribute to the development of efficient ACHE units designed for sCO2 power cycles. The finned-tube bundle is simplified, with a Porous Media Model representing the pressure drop through the bundle. Pressure inlet and -outlet boundary conditions are used, meaning the air flowrate is solved based on the fan and tube bundle interaction. The flowrate predicted by the CFD model is 0.5% higher than the analytical prediction, and 3.6% lower than the design value, demonstrating that the assumptions used in the design procedure are reasonable. The plenum height is also found to affect the flowrate, with shorter plenums resulting in higher flow rates and fan efficiencies, and longer plenums resulting in more uniform cooling air flow.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAxial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle
    typeJournal Paper
    journal volume147
    journal issue1
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4066248
    journal fristpage11019-1
    journal lastpage11019-9
    page9
    treeJournal of Engineering for Gas Turbines and Power:;2024:;volume( 147 ):;issue: 001
    contenttypeFulltext