description abstract | Biological cells are almost never truly spherical, even in the absence of an obvious cause that disrupts the cell’s symmetry. Using rather simple energy considerations, we show that even though all real biological cells are subject to a completely radial electric field along the cell membrane, the spherical shape is unstable under most practical situations. This simple result appears to have been overlooked in the literature. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Why Biological Cells Cannot Stay Spherical? | |
type | Journal Paper | |
journal volume | 91 | |
journal issue | 12 | |
journal title | Journal of Applied Mechanics | |
identifier doi | 10.1115/1.4066524 | |
journal fristpage | 121006-1 | |
journal lastpage | 121006-5 | |
page | 5 | |
tree | Journal of Applied Mechanics:;2024:;volume( 091 ):;issue: 012 | |
contenttype | Fulltext | |