    Analysis of Exergy Efficiency and Influencing Factors of Tube Heating Furnace in Oilfield Enterprises

    Source: Journal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 009::page 91010-1
    Author:
    Cheng, Qinglin
    ,
    Zhou, Ruiwen
    ,
    Wang, Lu
    ,
    Lv, Lili
    DOI: 10.1115/1.4065779
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In the energy consumption of surface engineering systems in oilfield enterprises, heating furnaces account for a significant proportion. Therefore, it is necessary to analyze and study their operational performance. This article conducts an exergy analysis of tubular heating furnaces from the perspective of energy quality. First, an exergy balance model and exergy analysis evaluation criteria are established for the energy system of the heating furnace. Then, the internal and external exergy losses in the heating furnace's energy system are comprehensively considered to identify weak points in the energy system and reflect the utilization of energy quality. The exergy analysis results show that the highest proportion of exergy losses in the heating furnace system is attributed to the heat transfer process. The excess air coefficient, exhaust temperature, and outer surface temperature of the furnace are inversely proportional to exergy efficiency. Based on the static exergy analysis results, measures to improve the exergy efficiency of the heating furnace are proposed: controlling the excess air coefficient within a reasonable range, reducing the exhaust temperature, and lowering outer surface temperature of the furnace. These measures can effectively enhance the energy utilization level of the tubular heating furnace and provide reference and assistance in meeting emission reduction requirements.
    • Download: (1.041Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Analysis of Exergy Efficiency and Influencing Factors of Tube Heating Furnace in Oilfield Enterprises

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4302623
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorCheng, Qinglin
    contributor authorZhou, Ruiwen
    contributor authorWang, Lu
    contributor authorLv, Lili
    date accessioned2024-12-24T18:43:20Z
    date available2024-12-24T18:43:20Z
    date copyright7/12/2024 12:00:00 AM
    date issued2024
    identifier issn1948-5085
    identifier othertsea_16_9_091010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4302623
    description abstractIn the energy consumption of surface engineering systems in oilfield enterprises, heating furnaces account for a significant proportion. Therefore, it is necessary to analyze and study their operational performance. This article conducts an exergy analysis of tubular heating furnaces from the perspective of energy quality. First, an exergy balance model and exergy analysis evaluation criteria are established for the energy system of the heating furnace. Then, the internal and external exergy losses in the heating furnace's energy system are comprehensively considered to identify weak points in the energy system and reflect the utilization of energy quality. The exergy analysis results show that the highest proportion of exergy losses in the heating furnace system is attributed to the heat transfer process. The excess air coefficient, exhaust temperature, and outer surface temperature of the furnace are inversely proportional to exergy efficiency. Based on the static exergy analysis results, measures to improve the exergy efficiency of the heating furnace are proposed: controlling the excess air coefficient within a reasonable range, reducing the exhaust temperature, and lowering outer surface temperature of the furnace. These measures can effectively enhance the energy utilization level of the tubular heating furnace and provide reference and assistance in meeting emission reduction requirements.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAnalysis of Exergy Efficiency and Influencing Factors of Tube Heating Furnace in Oilfield Enterprises
    typeJournal Paper
    journal volume16
    journal issue9
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4065779
    journal fristpage91010-1
    journal lastpage91010-12
    page12
    treeJournal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian