Investigation on the Influence of the Condenser Length and Its Coupling Effect With Elevation on the Performance of Loop Heat PipeSource: Journal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 006::page 61008-1DOI: 10.1115/1.4065130Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The effects of condenser length and evaporator/condenser elevation on the performance of a loop heat pipe (LHP) in a gravity field were investigated, respectively, as well as their coupling effect. The refrigerant R40 was selected, and the condenser length was altered by changing the number of fins connected to the water-cooled plates. The experiments were conducted at three evaporator/condenser elevations: zero elevation, favorable elevation, and adverse elevation. The experimental results indicated that the evaporator temperatures of LHP with three different condenser lengths are very close when the LHP operates in variable conductance mode (VCM). However, an excessively long condenser will increase the LHP thermal resistance in VCM. In constant conductance mode (CCM), the longer the condenser, the lower the evaporator temperature. As the heat load increases, the LHP first exhibits gravity-driven mode and then capillarity-gravity-driven mode at a favorable elevation. The positive coupling effect on reducing the evaporator temperature by extending the condenser length and running at a favorable elevation manifests that the influence of condenser length is very small in gravity-driven mode, while in capillarity-gravity-driven mode, the effect of operating at a favorable elevation gets weakened, and the positive effects of the two factors cannot be simply calculated by the linear superposition principle. Additionally, reverse flow and flash evaporation were also observed and analyzed in depth. These results and conclusions can be used to guide the design of the condenser and the installation of LHP for ground applications.
|
Show full item record
contributor author | Zhou, Xue | |
contributor author | Zheng, Suzheng | |
contributor author | Li, Nanxi | |
contributor author | Lin, Bingyao | |
contributor author | Chen, De | |
contributor author | Jiang, Zhenhua | |
contributor author | Lu, Yan | |
date accessioned | 2024-12-24T18:42:04Z | |
date available | 2024-12-24T18:42:04Z | |
date copyright | 4/16/2024 12:00:00 AM | |
date issued | 2024 | |
identifier issn | 1948-5085 | |
identifier other | tsea_16_6_061008.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4302586 | |
description abstract | The effects of condenser length and evaporator/condenser elevation on the performance of a loop heat pipe (LHP) in a gravity field were investigated, respectively, as well as their coupling effect. The refrigerant R40 was selected, and the condenser length was altered by changing the number of fins connected to the water-cooled plates. The experiments were conducted at three evaporator/condenser elevations: zero elevation, favorable elevation, and adverse elevation. The experimental results indicated that the evaporator temperatures of LHP with three different condenser lengths are very close when the LHP operates in variable conductance mode (VCM). However, an excessively long condenser will increase the LHP thermal resistance in VCM. In constant conductance mode (CCM), the longer the condenser, the lower the evaporator temperature. As the heat load increases, the LHP first exhibits gravity-driven mode and then capillarity-gravity-driven mode at a favorable elevation. The positive coupling effect on reducing the evaporator temperature by extending the condenser length and running at a favorable elevation manifests that the influence of condenser length is very small in gravity-driven mode, while in capillarity-gravity-driven mode, the effect of operating at a favorable elevation gets weakened, and the positive effects of the two factors cannot be simply calculated by the linear superposition principle. Additionally, reverse flow and flash evaporation were also observed and analyzed in depth. These results and conclusions can be used to guide the design of the condenser and the installation of LHP for ground applications. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Investigation on the Influence of the Condenser Length and Its Coupling Effect With Elevation on the Performance of Loop Heat Pipe | |
type | Journal Paper | |
journal volume | 16 | |
journal issue | 6 | |
journal title | Journal of Thermal Science and Engineering Applications | |
identifier doi | 10.1115/1.4065130 | |
journal fristpage | 61008-1 | |
journal lastpage | 61008-10 | |
page | 10 | |
tree | Journal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 006 | |
contenttype | Fulltext |