    Experimental Investigation of the Effect of Heat Pipe Tilting on a Concentrated Photovoltaic/Heat Pipe Passive Cooling System

    Source: Journal of Solar Energy Engineering:;2024:;volume( 146 ):;issue: 004::page 41010-1
    Author:
    Lashin, Abdelrahman
    ,
    Sabry, Mohamed
    DOI: 10.1115/1.4065297
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: To maintain the concentrated photovoltaic systems (CPV) output, effective cooling is necessary. In contrast to costly and complicated active cooling methods, passive cooling is static, simple, and maintenance-free. Among passive techniques, Heat Pipes (HPs) are devices that efficiently transfer heat from the evaporator to the condenser. The inclination angle of wicked, liquid-filled HP's long-axis determines how well it cools, as an effect of the gravitational force acting on the condensed liquid. This study investigates the effect of tilting the HP long-axis on the performance of the different parameters of the CPV, which is passively cooled by thermal attachment to its back side. Two similar HPs except for their lengths were attached alternatively. Different concentrated illumination levels are then allowed to be incident on the CPV. At each illumination level, the inclination of the HP long-axis was varied from −90 deg (completely vertical with condenser up) to 90 deg (completely vertical with condenser down), passing through 0 deg (HP is completely horizontal) with a step of 15 deg. The effect of such variations on the inclinations has been tested on the two systems. The system incorporating the long HP was found to have a higher cooling performance at an angle of −15 deg, compared to the short HP system, which has its highest cooling capacity at an angle of −60 deg, with an increase of about 7% for the maximum power in case of using the former system compared to the latter.
    • Download: (975.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Investigation of the Effect of Heat Pipe Tilting on a Concentrated Photovoltaic/Heat Pipe Passive Cooling System

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4302441
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorLashin, Abdelrahman
    contributor authorSabry, Mohamed
    date accessioned2024-12-24T18:36:48Z
    date available2024-12-24T18:36:48Z
    date copyright4/29/2024 12:00:00 AM
    date issued2024
    identifier issn0199-6231
    identifier othersol_146_4_041010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4302441
    description abstractTo maintain the concentrated photovoltaic systems (CPV) output, effective cooling is necessary. In contrast to costly and complicated active cooling methods, passive cooling is static, simple, and maintenance-free. Among passive techniques, Heat Pipes (HPs) are devices that efficiently transfer heat from the evaporator to the condenser. The inclination angle of wicked, liquid-filled HP's long-axis determines how well it cools, as an effect of the gravitational force acting on the condensed liquid. This study investigates the effect of tilting the HP long-axis on the performance of the different parameters of the CPV, which is passively cooled by thermal attachment to its back side. Two similar HPs except for their lengths were attached alternatively. Different concentrated illumination levels are then allowed to be incident on the CPV. At each illumination level, the inclination of the HP long-axis was varied from −90 deg (completely vertical with condenser up) to 90 deg (completely vertical with condenser down), passing through 0 deg (HP is completely horizontal) with a step of 15 deg. The effect of such variations on the inclinations has been tested on the two systems. The system incorporating the long HP was found to have a higher cooling performance at an angle of −15 deg, compared to the short HP system, which has its highest cooling capacity at an angle of −60 deg, with an increase of about 7% for the maximum power in case of using the former system compared to the latter.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Investigation of the Effect of Heat Pipe Tilting on a Concentrated Photovoltaic/Heat Pipe Passive Cooling System
    typeJournal Paper
    journal volume146
    journal issue4
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4065297
    journal fristpage41010-1
    journal lastpage41010-7
    page7
    treeJournal of Solar Energy Engineering:;2024:;volume( 146 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian