YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Straightness of Central Anatomical Axes of Human Tibia–Fibula System: Role of Fibula and Its Importance in Biomechanics

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2023:;volume( 007 ):;issue: 003::page 31006-1
    Author:
    Tiwari, Ashish
    ,
    Wahi, Pankaj
    ,
    Gupta, Shakti S.
    ,
    Sinha, Niraj
    DOI: 10.1115/1.4063649
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Fracture may occur in human lower leg bones considering varying loads acting on them while performing various functions. Implants, commonly used in healing the fractures, must be properly aligned with the bones' anatomical axes for their proper functioning. While attempts to establish tibial anatomical axis have been made previously, combined central anatomical axis of human tibia and fibula remains unexplored. In this study, profiles of individual and combined central anatomical axes of tibia and fibula have been obtained using computed tomography (CT). These profiles are found to be approximately straight with the deviation from straight line for the centroidal axis of the combined system being approximately half of that for the tibia. It is further utilized in assessing the role of fibula in determining the critical stresses in the tibia with the help of static finite element analysis (FEA) of a tibia–fibula model. Even though fibula takes a smaller proportion of the total axial load, its absence increases the compressive stresses in the tibia due to increased bending moments at the critical cross section. Furthermore, FEA has been carried out to understand the clinical significance of the mismatch in the centroidal axis of an implant and its parent bone taking the example of the human tibia alone. FEA suggests that these central anatomical axes are in fact the load bearing axes of the bones and any misalignment of implant with the central anatomical axis may lead to patient discomfort and premature failure of the implant.
    • Download: (2.549Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Straightness of Central Anatomical Axes of Human Tibia–Fibula System: Role of Fibula and Its Importance in Biomechanics

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295523
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorTiwari, Ashish
    contributor authorWahi, Pankaj
    contributor authorGupta, Shakti S.
    contributor authorSinha, Niraj
    date accessioned2024-04-24T22:36:25Z
    date available2024-04-24T22:36:25Z
    date copyright11/1/2023 12:00:00 AM
    date issued2023
    identifier issn2572-7958
    identifier otherjesmdt_007_03_031006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295523
    description abstractFracture may occur in human lower leg bones considering varying loads acting on them while performing various functions. Implants, commonly used in healing the fractures, must be properly aligned with the bones' anatomical axes for their proper functioning. While attempts to establish tibial anatomical axis have been made previously, combined central anatomical axis of human tibia and fibula remains unexplored. In this study, profiles of individual and combined central anatomical axes of tibia and fibula have been obtained using computed tomography (CT). These profiles are found to be approximately straight with the deviation from straight line for the centroidal axis of the combined system being approximately half of that for the tibia. It is further utilized in assessing the role of fibula in determining the critical stresses in the tibia with the help of static finite element analysis (FEA) of a tibia–fibula model. Even though fibula takes a smaller proportion of the total axial load, its absence increases the compressive stresses in the tibia due to increased bending moments at the critical cross section. Furthermore, FEA has been carried out to understand the clinical significance of the mismatch in the centroidal axis of an implant and its parent bone taking the example of the human tibia alone. FEA suggests that these central anatomical axes are in fact the load bearing axes of the bones and any misalignment of implant with the central anatomical axis may lead to patient discomfort and premature failure of the implant.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleStraightness of Central Anatomical Axes of Human Tibia–Fibula System: Role of Fibula and Its Importance in Biomechanics
    typeJournal Paper
    journal volume7
    journal issue3
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4063649
    journal fristpage31006-1
    journal lastpage31006-12
    page12
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2023:;volume( 007 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian