YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Applied Mechanics
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Applied Mechanics
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Curvature-Matching Mechanics in Skin-Based Bioelectronics to Minimize Interfacial Stresses

    Source: Journal of Applied Mechanics:;2023:;volume( 091 ):;issue: 004::page 45001-1
    Author:
    Avila, Raudel
    DOI: 10.1115/1.4064211
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A geometrical and mechanical design strategy is proposed for bioelectronics to improve wearability and comfort by reducing the magnitude of interfacial stresses and ensuring that the spatial stress distributions are below the somatosensory threshold for skin sensitivity. Conceptually, bioelectronic devices with soft polymeric encapsulations and internal rigid electronic components result in a mechanically hybrid composite structure, with intrinsically soft mechanics to facilitate integration with biological tissues through mechanical compliance. For accurate signal acquisition and sensing in curvilinear regions (e.g., limbs, chest, forehead), bioelectronic devices are pressed and bent to closely match the skin morphology, resulting in additional interfacial stresses. In the present work, we demonstrate how curvature-matching designs for the bioelectronic–skin interface can reduce the resulting normal and shear stresses generated from device adhesion and skin stretching during dynamic motions. Finite element modeling of the skin curvature, encapsulation, and internal electronic layouts was used to quantify the spatial distribution of the underlying stresses at the skin interface based on a mismatch curvature angle θ between the device and skin. The results show that curvature-matching designs for selected cases of θ = 30 deg and 60 deg can reduce the normal and shear stresses by up to 45% and 70%, respectively, even for a stretch of up to λ = 1.3. The proposed curvature-matching design strategy can inform the future design of user-specific bioelectronics to create anatomically compatible geometrical layouts that enhance mechanical compliance and enable physiological monitoring and integration in curved body structures.
    • Download: (1.412Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Curvature-Matching Mechanics in Skin-Based Bioelectronics to Minimize Interfacial Stresses

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295363
    Collections
    • Journal of Applied Mechanics

    Show full item record

    contributor authorAvila, Raudel
    date accessioned2024-04-24T22:31:00Z
    date available2024-04-24T22:31:00Z
    date copyright12/22/2023 12:00:00 AM
    date issued2023
    identifier issn0021-8936
    identifier otherjam_91_4_045001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295363
    description abstractA geometrical and mechanical design strategy is proposed for bioelectronics to improve wearability and comfort by reducing the magnitude of interfacial stresses and ensuring that the spatial stress distributions are below the somatosensory threshold for skin sensitivity. Conceptually, bioelectronic devices with soft polymeric encapsulations and internal rigid electronic components result in a mechanically hybrid composite structure, with intrinsically soft mechanics to facilitate integration with biological tissues through mechanical compliance. For accurate signal acquisition and sensing in curvilinear regions (e.g., limbs, chest, forehead), bioelectronic devices are pressed and bent to closely match the skin morphology, resulting in additional interfacial stresses. In the present work, we demonstrate how curvature-matching designs for the bioelectronic–skin interface can reduce the resulting normal and shear stresses generated from device adhesion and skin stretching during dynamic motions. Finite element modeling of the skin curvature, encapsulation, and internal electronic layouts was used to quantify the spatial distribution of the underlying stresses at the skin interface based on a mismatch curvature angle θ between the device and skin. The results show that curvature-matching designs for selected cases of θ = 30 deg and 60 deg can reduce the normal and shear stresses by up to 45% and 70%, respectively, even for a stretch of up to λ = 1.3. The proposed curvature-matching design strategy can inform the future design of user-specific bioelectronics to create anatomically compatible geometrical layouts that enhance mechanical compliance and enable physiological monitoring and integration in curved body structures.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCurvature-Matching Mechanics in Skin-Based Bioelectronics to Minimize Interfacial Stresses
    typeJournal Paper
    journal volume91
    journal issue4
    journal titleJournal of Applied Mechanics
    identifier doi10.1115/1.4064211
    journal fristpage45001-1
    journal lastpage45001-12
    page12
    treeJournal of Applied Mechanics:;2023:;volume( 091 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian