    Biomechanical Analysis of Mandibular Bone-Implant Construct With Three Implant Screw Design: A Finite Element Study

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2023:;volume( 006 ):;issue: 003::page 30905-1
    Author:
    Banerjee, Anik
    ,
    Choudhury, Sandeep
    ,
    Rana, Masud
    ,
    Chakraborty, Arindam
    ,
    Gupta, Abhisek
    ,
    Chowdhury, Amit Roy
    DOI: 10.1115/1.4062437
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Temporomandibular joint replacement (TMJR) is a surgical procedure that relies heavily on the biomechanical properties of the implant-bone interface for success. In this study, we investigated the effects of three commonly used implant screw thread designs (buttress, square, and triangle) on the biomechanical performance of the mandibular bone-implant construct, with the aim of improving osseointegration. Using finite element analysis, we simulated the mechanical behavior of the prosthesis and mandible and examined the biomechanics of the temporomandibular joint. We considered five coefficients of friction ranging from 0.1 to 0.5 in our analyses. Our hypothesis was that changing the screw thread shape while keeping the pitch, height, and depth constant could enhance the biomechanical environment at the peri-implant bone. Our results indicate that the square thread design produced the highest stress concentration, while the triangle thread design exhibited the most favorable distribution of stress around the implant. Furthermore, increasing the coefficient of friction led to an increase in stress concentration in the implant and surrounding bone. Our findings offer valuable insights into the biomechanical performance of different screw thread designs in the mandibular bone-implant construct. They highlight the significance of considering screw thread shape and coefficient of friction in TMJR implant design. Future studies should incorporate the viscoelastic properties of bone to improve the accuracy of finite element analysis. This research contributes to the optimization of TMJR implants and ultimately enhances patient outcomes.
    • Download: (1.248Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Biomechanical Analysis of Mandibular Bone-Implant Construct With Three Implant Screw Design: A Finite Element Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294607
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorBanerjee, Anik
    contributor authorChoudhury, Sandeep
    contributor authorRana, Masud
    contributor authorChakraborty, Arindam
    contributor authorGupta, Abhisek
    contributor authorChowdhury, Amit Roy
    date accessioned2023-11-29T19:08:26Z
    date available2023-11-29T19:08:26Z
    date copyright5/18/2023 12:00:00 AM
    date issued5/18/2023 12:00:00 AM
    date issued2023-05-18
    identifier issn2572-7958
    identifier otherjesmdt_006_03_030905.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294607
    description abstractTemporomandibular joint replacement (TMJR) is a surgical procedure that relies heavily on the biomechanical properties of the implant-bone interface for success. In this study, we investigated the effects of three commonly used implant screw thread designs (buttress, square, and triangle) on the biomechanical performance of the mandibular bone-implant construct, with the aim of improving osseointegration. Using finite element analysis, we simulated the mechanical behavior of the prosthesis and mandible and examined the biomechanics of the temporomandibular joint. We considered five coefficients of friction ranging from 0.1 to 0.5 in our analyses. Our hypothesis was that changing the screw thread shape while keeping the pitch, height, and depth constant could enhance the biomechanical environment at the peri-implant bone. Our results indicate that the square thread design produced the highest stress concentration, while the triangle thread design exhibited the most favorable distribution of stress around the implant. Furthermore, increasing the coefficient of friction led to an increase in stress concentration in the implant and surrounding bone. Our findings offer valuable insights into the biomechanical performance of different screw thread designs in the mandibular bone-implant construct. They highlight the significance of considering screw thread shape and coefficient of friction in TMJR implant design. Future studies should incorporate the viscoelastic properties of bone to improve the accuracy of finite element analysis. This research contributes to the optimization of TMJR implants and ultimately enhances patient outcomes.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleBiomechanical Analysis of Mandibular Bone-Implant Construct With Three Implant Screw Design: A Finite Element Study
    typeJournal Paper
    journal volume6
    journal issue3
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4062437
    journal fristpage30905-1
    journal lastpage30905-6
    page6
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2023:;volume( 006 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian