YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Characterization of a Lightly Loaded Underfloor Catalyzed Gasoline Particulate Filter in a Turbocharged Light Duty Truck

    Source: Journal of Engineering for Gas Turbines and Power:;2022:;volume( 145 ):;issue: 002::page 21024-1
    Author:
    Bohac, Stanislav V.
    ,
    Ludlam, Scott
    DOI: 10.1115/1.4056047
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A test program to characterize the benefits and challenges of applying a European series production catalyzed gasoline particulate filter (GPF) to a U.S. Tier 2 turbocharged light duty truck (3.5 L Ecoboost Ford F150) in the underfloor location was initiated at the U.S. Environmental Protection Agency. The turbos and underfloor location keep the GPF relatively cool and minimize passive regeneration relative to other configurations. This study characterizes the relatively cool GPF in a lightly loaded state, approximately 0.1–0.4 g/L of soot loading, using four test cycles: 60 mph steady-state, 4-phase Federal Test Procedure city drive cycle (FTP), highway dirve cycle, and US06. Measurements include GPF temperature, soot loading, GPF pressure drop, brake thermal efficiency (BTE), CO2, particulate matter (PM) mass, elemental carbon (EC), filter-collected organic carbon (OC), CO, total hydrocarbons (THC), and NOx emissions. The lightly loaded underfloor GPF achieves an 85–99% reduction in PM mass, a 98.5–100.0% reduction in EC, and a 65–91% reduction in filter-collected OC, depending on test cycle. The smallest reductions in PM and EC occur in the US06 cycle due to mild GPF regeneration caused by GPF inlet temperature exceeding 500 °C. EC dominates filter-collected OC without a GPF, while OC dominates EC with a GPF. Composite cycle CO, THC, and NOx emissions are reduced by the washcoat on the GPF but the low temperature location of the GPF does not make best use of the catalyzed washcoat. Cycle average pressure drop across the GPF ranged from 1.25 kPa in the four-phase FTP to 4.64 kPa in the US06 but did not affect BTE or CO2 emissions in a measurable way in any test cycle.
    • Download: (1.381Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Characterization of a Lightly Loaded Underfloor Catalyzed Gasoline Particulate Filter in a Turbocharged Light Duty Truck

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294287
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorBohac, Stanislav V.
    contributor authorLudlam, Scott
    date accessioned2023-11-29T18:38:43Z
    date available2023-11-29T18:38:43Z
    date copyright11/29/2022 12:00:00 AM
    date issued11/29/2022 12:00:00 AM
    date issued2022-11-29
    identifier issn0742-4795
    identifier othergtp_145_02_021024.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294287
    description abstractA test program to characterize the benefits and challenges of applying a European series production catalyzed gasoline particulate filter (GPF) to a U.S. Tier 2 turbocharged light duty truck (3.5 L Ecoboost Ford F150) in the underfloor location was initiated at the U.S. Environmental Protection Agency. The turbos and underfloor location keep the GPF relatively cool and minimize passive regeneration relative to other configurations. This study characterizes the relatively cool GPF in a lightly loaded state, approximately 0.1–0.4 g/L of soot loading, using four test cycles: 60 mph steady-state, 4-phase Federal Test Procedure city drive cycle (FTP), highway dirve cycle, and US06. Measurements include GPF temperature, soot loading, GPF pressure drop, brake thermal efficiency (BTE), CO2, particulate matter (PM) mass, elemental carbon (EC), filter-collected organic carbon (OC), CO, total hydrocarbons (THC), and NOx emissions. The lightly loaded underfloor GPF achieves an 85–99% reduction in PM mass, a 98.5–100.0% reduction in EC, and a 65–91% reduction in filter-collected OC, depending on test cycle. The smallest reductions in PM and EC occur in the US06 cycle due to mild GPF regeneration caused by GPF inlet temperature exceeding 500 °C. EC dominates filter-collected OC without a GPF, while OC dominates EC with a GPF. Composite cycle CO, THC, and NOx emissions are reduced by the washcoat on the GPF but the low temperature location of the GPF does not make best use of the catalyzed washcoat. Cycle average pressure drop across the GPF ranged from 1.25 kPa in the four-phase FTP to 4.64 kPa in the US06 but did not affect BTE or CO2 emissions in a measurable way in any test cycle.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCharacterization of a Lightly Loaded Underfloor Catalyzed Gasoline Particulate Filter in a Turbocharged Light Duty Truck
    typeJournal Paper
    journal volume145
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4056047
    journal fristpage21024-1
    journal lastpage21024-7
    page7
    treeJournal of Engineering for Gas Turbines and Power:;2022:;volume( 145 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian