    Design Considerations for Vertical Bifacial Agrivoltaic Installations

    Source: Journal of Solar Energy Engineering:;2023:;volume( 145 ):;issue: 006::page 61007-1
    Author:
    Ross Rucker, W.
    ,
    Birnie, Dunbar P., III
    DOI: 10.1115/1.4062323
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The expected annual energy output of vertical bifacial solar panel arrays was modeled with an eye on how array design attributes affect the output. We considered module height, cell density (single- or double-high racking), inter-row spacing, and inverter connection (rows of modules wired together or separately), and the inclusion of bypass diodes. We observed that these design choices have a substantial impact on the annual energy yield on a per-module basis and per-acre basis. We modeled the instantaneous brightness and shading based on the position of the sun and adjacent rows of modules, which caused nonuniform irradiance due to inter-row shading effects. Based on the irradiance, we calculated current, voltage, and power values throughout a year for different design strategies. Double-high racking, which uses two landscape-oriented modules stacked vertically, offers noteworthy power gains per acre with only a modest increase of inter-row shading. When bypass diodes are included in the module design and improved inverter wiring is used, much of the loss due to inter-row shading is mitigated, and the total power output per acre is nearly doubled, with modules seeing an 80% power increase per acre for 20 ft row spacing, and over 90% power increase per acre for 40 ft spacing.
    • Download: (1.580Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design Considerations for Vertical Bifacial Agrivoltaic Installations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292606
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorRoss Rucker, W.
    contributor authorBirnie, Dunbar P., III
    date accessioned2023-08-16T18:51:41Z
    date available2023-08-16T18:51:41Z
    date copyright5/2/2023 12:00:00 AM
    date issued2023
    identifier issn0199-6231
    identifier othersol_145_6_061007.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292606
    description abstractThe expected annual energy output of vertical bifacial solar panel arrays was modeled with an eye on how array design attributes affect the output. We considered module height, cell density (single- or double-high racking), inter-row spacing, and inverter connection (rows of modules wired together or separately), and the inclusion of bypass diodes. We observed that these design choices have a substantial impact on the annual energy yield on a per-module basis and per-acre basis. We modeled the instantaneous brightness and shading based on the position of the sun and adjacent rows of modules, which caused nonuniform irradiance due to inter-row shading effects. Based on the irradiance, we calculated current, voltage, and power values throughout a year for different design strategies. Double-high racking, which uses two landscape-oriented modules stacked vertically, offers noteworthy power gains per acre with only a modest increase of inter-row shading. When bypass diodes are included in the module design and improved inverter wiring is used, much of the loss due to inter-row shading is mitigated, and the total power output per acre is nearly doubled, with modules seeing an 80% power increase per acre for 20 ft row spacing, and over 90% power increase per acre for 40 ft spacing.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign Considerations for Vertical Bifacial Agrivoltaic Installations
    typeJournal Paper
    journal volume145
    journal issue6
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4062323
    journal fristpage61007-1
    journal lastpage61007-11
    page11
    treeJournal of Solar Energy Engineering:;2023:;volume( 145 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian