YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Thermal Science and Engineering Applications
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Thermal Science and Engineering Applications
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Optimized Film Cooling Flow on a Contoured Endwall Within a Transonic Annular Cascade

    Source: Journal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 004::page 41011-1
    Author:
    Burdett, Timothy A.
    ,
    Ullah, Izhar
    ,
    Wright, Lesley M.
    ,
    Han, Je-Chin
    ,
    McClintic, John W.
    ,
    Crites, Daniel C.
    ,
    Riahi, Ardeshir
    DOI: 10.1115/1.4056839
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Film cooling was measured on the endwall of a five-vane annular cascade in a blowdown wind tunnel at an exit Mach number of 0.9. The adiabatic film cooling effectiveness was calculated from the partial pressure of oxygen measured with binary pressure-sensitive paint (BPSP). Cylindrical film cooling holes were located in the upstream and passage regions with the coolant-to-mainstream mass flow ratio (MFR) independently varied for each region. One row was located upstream of the vanes and supplied by an upstream plenum. Two rows were located in the passage between two vanes and supplied by a downstream plenum. Three total MFRs were investigated: 1%, 1.5%, and 2%. For a given total MFR, four combinations of upstream and downstream MFRs were compared to an even split of coolant. Coolant-to-mainstream density ratios (DRs) of 1.0 and 2.0 were investigated. The most efficient use of coolant hinged on balancing the downstream MFR for the second row due to the endwall pressure gradient preventing coolant from exiting the holes or a high jet velocity causing liftoff. For this row, selecting the optimum MFR increased the area-averaged film cooling effectiveness by up to 200% with a reduction in row 1 of less than 25%. At high downstream MFRs, increasing the density ratio delayed liftoff and increased film cooling effectiveness in row 2 by 65%. However, at low MFRs, increasing the density ratio reduced film cooling effectiveness in row 2 by 60%.
    • Download: (1.374Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Optimized Film Cooling Flow on a Contoured Endwall Within a Transonic Annular Cascade

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4291443
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorBurdett, Timothy A.
    contributor authorUllah, Izhar
    contributor authorWright, Lesley M.
    contributor authorHan, Je-Chin
    contributor authorMcClintic, John W.
    contributor authorCrites, Daniel C.
    contributor authorRiahi, Ardeshir
    date accessioned2023-08-16T18:07:04Z
    date available2023-08-16T18:07:04Z
    date copyright3/2/2023 12:00:00 AM
    date issued2023
    identifier issn1948-5085
    identifier othertsea_15_4_041011.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4291443
    description abstractFilm cooling was measured on the endwall of a five-vane annular cascade in a blowdown wind tunnel at an exit Mach number of 0.9. The adiabatic film cooling effectiveness was calculated from the partial pressure of oxygen measured with binary pressure-sensitive paint (BPSP). Cylindrical film cooling holes were located in the upstream and passage regions with the coolant-to-mainstream mass flow ratio (MFR) independently varied for each region. One row was located upstream of the vanes and supplied by an upstream plenum. Two rows were located in the passage between two vanes and supplied by a downstream plenum. Three total MFRs were investigated: 1%, 1.5%, and 2%. For a given total MFR, four combinations of upstream and downstream MFRs were compared to an even split of coolant. Coolant-to-mainstream density ratios (DRs) of 1.0 and 2.0 were investigated. The most efficient use of coolant hinged on balancing the downstream MFR for the second row due to the endwall pressure gradient preventing coolant from exiting the holes or a high jet velocity causing liftoff. For this row, selecting the optimum MFR increased the area-averaged film cooling effectiveness by up to 200% with a reduction in row 1 of less than 25%. At high downstream MFRs, increasing the density ratio delayed liftoff and increased film cooling effectiveness in row 2 by 65%. However, at low MFRs, increasing the density ratio reduced film cooling effectiveness in row 2 by 60%.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleOptimized Film Cooling Flow on a Contoured Endwall Within a Transonic Annular Cascade
    typeJournal Paper
    journal volume15
    journal issue4
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4056839
    journal fristpage41011-1
    journal lastpage41011-9
    page9
    treeJournal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian