    Effects of Upstream Step Geometries on Endwall Film Cooling and Phantom Cooling Performances of a Transonic Turbine Vane

    Source: Journal of Thermal Science and Engineering Applications:;2022:;volume( 014 ):;issue: 012::page 121005
    Author:
    Bai, Bo;Li, Zhigang;Li, Jun;Mao, Shuo;Ng, Wing F.
    DOI: 10.1115/1.4055006
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In gas turbine engines, the endwall misalignment (step geometries with various step heights) commonly exists between the combustor exit and the first nozzle guide vane endwall, due to assembly error, metal corrosion, and thermal expansion. The step geometries affect the secondary flow field near the endwall and coolant flow behavior, thereby leading to a significant variation in endwall film cooling, vane surface phantom cooling, and vane passage aerodynamic performances. This paper presents a detailed experimental and numerical study on endwall film cooling and vane pressure side surface phantom cooling at simulated gas turbine operating conditions (high inlet freestream turbulence level of 16%, exit Mach number of 0.85, and exit Reynolds number of 1.7 × 106). The experimental measurements were conducted at Virginia Tech’s transonic blowdown wind tunnel for two configurations: baseline cascade (HR = 0) and forwardfacing step geometry (HR = −0.1). The numerical predictions were performed by solving the steadystate Reynoldsaveraged Navier Stokes (RANS) with realizable k–ɛ turbulence model. Based on a double coolant temperature model, a novel numerical method for the predictions of adiabatic wall film cooling effectiveness was proposed. The qualitative and quantitative comparisons between the numerical prediction results and experimental data are provided in this paper. The results indicate that this method can reliably predict endwall film cooling distributions and vane pressure side surface phantom cooling distributions, and significantly reduce (more than 50%) numerical prediction errors. The effects of upstream step geometries were numerically studied at the design flow conditions (BR = 2.5, DR = 1.2), by quantizing the endwall film cooling effectiveness, endwall net heat flux reduction (NHFR), vane pressure side surface phantom cooling effectiveness, and total pressure loss coefficients (TPLC) for various upstream step heights: three forwardfacing step heights (HR = −0.16, −0.1, and −0.06), a baseline cascade (HR = 0), and four backwardfacing step heights (HR = 0.06, 0.1, 0.136, and 0.2). Results show the upstream forwardfacing step geometry is beneficial for enhancing endwall film cooling (maximum enhancement level of 15%), endwall net heat flux reduction (maximum enhancement level of 10%), and vane pressure side surface phantom cooling (maximum enhancement level of 66.7%). Nevertheless, the upstream backwardfacing step geometry is pernicious to the endwall film cooling, endwall heat flux reduction, and phantom cooling, and these pernicious effects have sharply deteriorated when the upstream step height is larger than a critical value (HR > 0.136). To be specific, the film cooling effectiveness (from 30% to 80%), net heat flux reduction (up to 78%), and phantom cooling effectiveness (completely disappeared) significantly decrease by introducing an overlarge backwardfacing step height HR = 0.2. The upstream step geometries lead to deteriorated aerodynamic performance, though the reduction level may be slight (0.36% at HR = 0.136). These suggest that the overlarge backwardfacing misalignment will increase the risk of thermal failure and must be avoided during the component assembly and the operational processes of a gas turbine.
    • Download: (3.981Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effects of Upstream Step Geometries on Endwall Film Cooling and Phantom Cooling Performances of a Transonic Turbine Vane

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4288905
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorBai, Bo;Li, Zhigang;Li, Jun;Mao, Shuo;Ng, Wing F.
    date accessioned2023-04-06T13:00:19Z
    date available2023-04-06T13:00:19Z
    date copyright8/24/2022 12:00:00 AM
    date issued2022
    identifier issn19485085
    identifier othertsea_14_12_121005.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4288905
    description abstractIn gas turbine engines, the endwall misalignment (step geometries with various step heights) commonly exists between the combustor exit and the first nozzle guide vane endwall, due to assembly error, metal corrosion, and thermal expansion. The step geometries affect the secondary flow field near the endwall and coolant flow behavior, thereby leading to a significant variation in endwall film cooling, vane surface phantom cooling, and vane passage aerodynamic performances. This paper presents a detailed experimental and numerical study on endwall film cooling and vane pressure side surface phantom cooling at simulated gas turbine operating conditions (high inlet freestream turbulence level of 16%, exit Mach number of 0.85, and exit Reynolds number of 1.7 × 106). The experimental measurements were conducted at Virginia Tech’s transonic blowdown wind tunnel for two configurations: baseline cascade (HR = 0) and forwardfacing step geometry (HR = −0.1). The numerical predictions were performed by solving the steadystate Reynoldsaveraged Navier Stokes (RANS) with realizable k–ɛ turbulence model. Based on a double coolant temperature model, a novel numerical method for the predictions of adiabatic wall film cooling effectiveness was proposed. The qualitative and quantitative comparisons between the numerical prediction results and experimental data are provided in this paper. The results indicate that this method can reliably predict endwall film cooling distributions and vane pressure side surface phantom cooling distributions, and significantly reduce (more than 50%) numerical prediction errors. The effects of upstream step geometries were numerically studied at the design flow conditions (BR = 2.5, DR = 1.2), by quantizing the endwall film cooling effectiveness, endwall net heat flux reduction (NHFR), vane pressure side surface phantom cooling effectiveness, and total pressure loss coefficients (TPLC) for various upstream step heights: three forwardfacing step heights (HR = −0.16, −0.1, and −0.06), a baseline cascade (HR = 0), and four backwardfacing step heights (HR = 0.06, 0.1, 0.136, and 0.2). Results show the upstream forwardfacing step geometry is beneficial for enhancing endwall film cooling (maximum enhancement level of 15%), endwall net heat flux reduction (maximum enhancement level of 10%), and vane pressure side surface phantom cooling (maximum enhancement level of 66.7%). Nevertheless, the upstream backwardfacing step geometry is pernicious to the endwall film cooling, endwall heat flux reduction, and phantom cooling, and these pernicious effects have sharply deteriorated when the upstream step height is larger than a critical value (HR > 0.136). To be specific, the film cooling effectiveness (from 30% to 80%), net heat flux reduction (up to 78%), and phantom cooling effectiveness (completely disappeared) significantly decrease by introducing an overlarge backwardfacing step height HR = 0.2. The upstream step geometries lead to deteriorated aerodynamic performance, though the reduction level may be slight (0.36% at HR = 0.136). These suggest that the overlarge backwardfacing misalignment will increase the risk of thermal failure and must be avoided during the component assembly and the operational processes of a gas turbine.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffects of Upstream Step Geometries on Endwall Film Cooling and Phantom Cooling Performances of a Transonic Turbine Vane
    typeJournal Paper
    journal volume14
    journal issue12
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4055006
    journal fristpage121005
    journal lastpage12100523
    page23
    treeJournal of Thermal Science and Engineering Applications:;2022:;volume( 014 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian