    Preheating Effects on Compression Ignition Engine Through Waste Heat Recovery Using THNF-Based Radiator Coolant: An Experimental Study

    Source: Journal of Thermal Science and Engineering Applications:;2022:;volume( 014 ):;issue: 012::page 121004
    Author:
    Kumar, Vikash;Sahoo, RashmiRekha
    DOI: 10.1115/1.4055005
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The present paper focuses on the thermohydraulic performance of a car radiator using Al2O3, CuO, and TiO2 nanoparticles disseminated in an equal fraction in the range of 0.06–0.12% called Ternary hybrid nanofluid (THNF), in water-based fluid, operated at coolant flowrate (CFR) range of 3–8 lpm and fan air velocity of 0.25–1.25 m/s). Moreover, a detailed accentuation has been given on the extensive nanofluid characterization mainly thermophysical properties and its stability, to justify nanofluid durability for the long run (scanning electron microscope, Zeta potential). Performance evaluation criteria (PEC) and friction factors were analyzed to evaluate the penalty in pressure drop for the heat transfer enhancement achieved. The experimental analysis revealed a maximum heat transfer enhancement in the coolant of 14.2% at CFR of 6lpm using 0.12% vol. fraction of THNF. The PEC value found within the limit of 1.0045–1.098 indicates a remarkable heat transfer enhancement on nanoparticle addition. Concurrently fuel elevated temperature improved thermal efficiency by 13.6% at 0.25 m/s of frontal air velocity during a maximum fuel-saving of 14.28% at 50% load on the engine. Hence, the preheating of fuel through the radiator waste heat improves the thermal efficiency, lowers the brake-specific fuel consumption, and saves fuel consumption successfully.
    • Download: (1.737Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Preheating Effects on Compression Ignition Engine Through Waste Heat Recovery Using THNF-Based Radiator Coolant: An Experimental Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4288436
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorKumar, Vikash;Sahoo, RashmiRekha
    date accessioned2022-12-27T23:20:58Z
    date available2022-12-27T23:20:58Z
    date copyright8/24/2022 12:00:00 AM
    date issued2022
    identifier issn1948-5085
    identifier othertsea_14_12_121004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4288436
    description abstractThe present paper focuses on the thermohydraulic performance of a car radiator using Al2O3, CuO, and TiO2 nanoparticles disseminated in an equal fraction in the range of 0.06–0.12% called Ternary hybrid nanofluid (THNF), in water-based fluid, operated at coolant flowrate (CFR) range of 3–8 lpm and fan air velocity of 0.25–1.25 m/s). Moreover, a detailed accentuation has been given on the extensive nanofluid characterization mainly thermophysical properties and its stability, to justify nanofluid durability for the long run (scanning electron microscope, Zeta potential). Performance evaluation criteria (PEC) and friction factors were analyzed to evaluate the penalty in pressure drop for the heat transfer enhancement achieved. The experimental analysis revealed a maximum heat transfer enhancement in the coolant of 14.2% at CFR of 6lpm using 0.12% vol. fraction of THNF. The PEC value found within the limit of 1.0045–1.098 indicates a remarkable heat transfer enhancement on nanoparticle addition. Concurrently fuel elevated temperature improved thermal efficiency by 13.6% at 0.25 m/s of frontal air velocity during a maximum fuel-saving of 14.28% at 50% load on the engine. Hence, the preheating of fuel through the radiator waste heat improves the thermal efficiency, lowers the brake-specific fuel consumption, and saves fuel consumption successfully.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePreheating Effects on Compression Ignition Engine Through Waste Heat Recovery Using THNF-Based Radiator Coolant: An Experimental Study
    typeJournal Paper
    journal volume14
    journal issue12
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4055005
    journal fristpage121004
    journal lastpage121004_16
    page16
    treeJournal of Thermal Science and Engineering Applications:;2022:;volume( 014 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian