    A Combined Liquid Cold Plate and Heat Sink Based Hybrid Cooling Approach for the Temperature Control of Integrated Circuit Chips

    Source: Journal of Thermal Science and Engineering Applications:;2022:;volume( 014 ):;issue: 011::page 111013-1
    Author:
    Patil
    ,
    Naveen G.;Hotta
    ,
    Tapano Kumar
    DOI: 10.1115/1.4054849
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The study focuses on the experimental and numerical investigations on the cooling of seven protruding asymmetric integrated circuit (IC) chips arranged optimally at various positions in a switch mode power supply (SMPS) board. The chips are cooled under the laminar forced convection mode using the hybrid cooling technique (liquid cold plate integrated with the heat sinks). Fifteen heat sink cases (combinations) are considered for the analysis with the goal to keep the IC chip’s temperature under the safe limit (less than 100 °C). Variable power (heat) inputs to the IC chips along with a water flow rate of 0.5 kg/s (corresponding to the velocity of 4 m/s) inside the liquid cold plate are considered for the analysis. The heat sinks absorb the heat dissipated from the IC chips and reduce their temperature substantially by enhancing their heat removal rate up to 32%. The convection contribution of the IC chips has also improved by 62% using the heat sinks. Hence, hybrid cooling is found to be an effective technique for the temperature control of the IC chips. Numerical analyses are also carried out using the ansys fluent (v r16) to support the experiments. Both the results agree with each other in the error band of 6–12%.
    • Download: (1.571Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Combined Liquid Cold Plate and Heat Sink Based Hybrid Cooling Approach for the Temperature Control of Integrated Circuit Chips

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4286942
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorPatil
    contributor authorNaveen G.;Hotta
    contributor authorTapano Kumar
    date accessioned2022-08-18T12:50:07Z
    date available2022-08-18T12:50:07Z
    date copyright7/18/2022 12:00:00 AM
    date issued2022
    identifier issn1948-5085
    identifier othertsea_14_11_111013.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286942
    description abstractThe study focuses on the experimental and numerical investigations on the cooling of seven protruding asymmetric integrated circuit (IC) chips arranged optimally at various positions in a switch mode power supply (SMPS) board. The chips are cooled under the laminar forced convection mode using the hybrid cooling technique (liquid cold plate integrated with the heat sinks). Fifteen heat sink cases (combinations) are considered for the analysis with the goal to keep the IC chip’s temperature under the safe limit (less than 100 °C). Variable power (heat) inputs to the IC chips along with a water flow rate of 0.5 kg/s (corresponding to the velocity of 4 m/s) inside the liquid cold plate are considered for the analysis. The heat sinks absorb the heat dissipated from the IC chips and reduce their temperature substantially by enhancing their heat removal rate up to 32%. The convection contribution of the IC chips has also improved by 62% using the heat sinks. Hence, hybrid cooling is found to be an effective technique for the temperature control of the IC chips. Numerical analyses are also carried out using the ansys fluent (v r16) to support the experiments. Both the results agree with each other in the error band of 6–12%.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Combined Liquid Cold Plate and Heat Sink Based Hybrid Cooling Approach for the Temperature Control of Integrated Circuit Chips
    typeJournal Paper
    journal volume14
    journal issue11
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4054849
    journal fristpage111013-1
    journal lastpage111013-13
    page13
    treeJournal of Thermal Science and Engineering Applications:;2022:;volume( 014 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian