YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Comparison of Blind Diagnostic Indicators for Condition Monitoring of Wind Turbine Gearbox Bearings

    Source: Journal of Engineering for Gas Turbines and Power:;2022:;volume( 144 ):;issue: 004::page 41019-1
    Author:
    Qi, Junyu
    ,
    Mauricio, Alexandre
    ,
    Gryllias, Konstantinos
    DOI: 10.1115/1.4049797
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Under the pressure of climate change, renewable energy gradually replaces fossil fuels and plays nowadays a significant role in energy production. Among different types of energy sources, wind power covered 14% of the EU's electricity demand in 2018. The Operations and Maintenance (O&
     
    M) costs of wind turbines may easily reach up to 20–25% of the total leverised cost per kWh produced over the lifetime of the turbine for a new unit. According to Wood Mackenzie Power &
     
    Renewables onshore wind farm operators are expected to spend nearly $15 billion on O&
     
    M services in 2019. Manufacturers and operators try to reduce O&
     
    M on one hand by developing new turbine designs and on the other hand by adopting condition monitoring approaches. One of the most critical and rather complex assemblies of wind turbines is the gearbox. Gearboxes are designed to last till the end of asset's lifetime, according to the IEC 61400-4 standards. On the other hand, a recent study over approximately 350 offshore wind turbines indicated that gearboxes might have to be replaced as early as 6.5 years. Therefore a plethora of sensor types and signal processing methodologies have been proposed in order to accurately detect and diagnose the presence of a fault. Among others, envelope analysis is one of the most important methodologies, where an envelope of the vibration signal is estimated, usually after filtering around a selected frequency band excited by impacts due to the fault. Sometimes the gearbox is equipped with many acceleration sensors and its kinematics is clearly known. In these cases cyclostationary analysis and the corresponding methodologies, i.e., the cyclic spectral correlation and the cyclic spectral coherence, have been proposed as powerful tools. On the other hand often the gearbox is equipped with a limited number of sensors and a simple global diagnostic indicator is demanded, being capable to detect globally various faults of different components. The scope of this paper is the application and comparison of a number of blind global diagnostic indicators which are based on Entropy (permutation entropy, approximate entropy, samples entropy, fuzzy entropy, conditional entropy, and Wiener entropy), on Negentropy (Infogram), on Sparsity (Sparse-L2/L1, Sparse-L1/L0, and Sparse-Gini index) and on Statistics (mean, standard deviation, kurtosis, etc.). The performance of the indicators is evaluated and compared on a wind turbine dataset, consisted of vibration data captured by one accelerometer mounted on six 2.5 MW wind turbines, located in a wind park in northern Sweden, where two different bearing faults have been filed, for one wind turbine, during a period of 46 months. Among the different diagnostic indicators permutation entropy, approximate entropy, samples entropy, fuzzy entropy, conditional entropy, and Wiener entropy achieve the best results detecting blindly the two failure events.
     
    • Download: (2.989Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Comparison of Blind Diagnostic Indicators for Condition Monitoring of Wind Turbine Gearbox Bearings

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4285005
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorQi, Junyu
    contributor authorMauricio, Alexandre
    contributor authorGryllias, Konstantinos
    date accessioned2022-05-08T09:20:02Z
    date available2022-05-08T09:20:02Z
    date copyright2/21/2022 12:00:00 AM
    date issued2022
    identifier issn0742-4795
    identifier othergtp_144_04_041019.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285005
    description abstractUnder the pressure of climate change, renewable energy gradually replaces fossil fuels and plays nowadays a significant role in energy production. Among different types of energy sources, wind power covered 14% of the EU's electricity demand in 2018. The Operations and Maintenance (O&
    description abstractM) costs of wind turbines may easily reach up to 20–25% of the total leverised cost per kWh produced over the lifetime of the turbine for a new unit. According to Wood Mackenzie Power &
    description abstractRenewables onshore wind farm operators are expected to spend nearly $15 billion on O&
    description abstractM services in 2019. Manufacturers and operators try to reduce O&
    description abstractM on one hand by developing new turbine designs and on the other hand by adopting condition monitoring approaches. One of the most critical and rather complex assemblies of wind turbines is the gearbox. Gearboxes are designed to last till the end of asset's lifetime, according to the IEC 61400-4 standards. On the other hand, a recent study over approximately 350 offshore wind turbines indicated that gearboxes might have to be replaced as early as 6.5 years. Therefore a plethora of sensor types and signal processing methodologies have been proposed in order to accurately detect and diagnose the presence of a fault. Among others, envelope analysis is one of the most important methodologies, where an envelope of the vibration signal is estimated, usually after filtering around a selected frequency band excited by impacts due to the fault. Sometimes the gearbox is equipped with many acceleration sensors and its kinematics is clearly known. In these cases cyclostationary analysis and the corresponding methodologies, i.e., the cyclic spectral correlation and the cyclic spectral coherence, have been proposed as powerful tools. On the other hand often the gearbox is equipped with a limited number of sensors and a simple global diagnostic indicator is demanded, being capable to detect globally various faults of different components. The scope of this paper is the application and comparison of a number of blind global diagnostic indicators which are based on Entropy (permutation entropy, approximate entropy, samples entropy, fuzzy entropy, conditional entropy, and Wiener entropy), on Negentropy (Infogram), on Sparsity (Sparse-L2/L1, Sparse-L1/L0, and Sparse-Gini index) and on Statistics (mean, standard deviation, kurtosis, etc.). The performance of the indicators is evaluated and compared on a wind turbine dataset, consisted of vibration data captured by one accelerometer mounted on six 2.5 MW wind turbines, located in a wind park in northern Sweden, where two different bearing faults have been filed, for one wind turbine, during a period of 46 months. Among the different diagnostic indicators permutation entropy, approximate entropy, samples entropy, fuzzy entropy, conditional entropy, and Wiener entropy achieve the best results detecting blindly the two failure events.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparison of Blind Diagnostic Indicators for Condition Monitoring of Wind Turbine Gearbox Bearings
    typeJournal Paper
    journal volume144
    journal issue4
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4049797
    journal fristpage41019-1
    journal lastpage41019-9
    page9
    treeJournal of Engineering for Gas Turbines and Power:;2022:;volume( 144 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian