    Effect of Die Clearance on Peak Punching Force During Cryogenic Micropunching of Polycaprolactone

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2020:;volume( 004 ):;issue: 001::page 011004-1
    Author:
    Sagar, Amrit
    ,
    Nehme, Christopher
    ,
    Saigal, Anil
    ,
    James, Thomas P.
    DOI: 10.1115/1.4049106
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Microscale holes were punched at cryogenic conditions in polycaprolactone (PCL) membranes to create synthetic three-dimensional (3D) tissue scaffolds through multilayer stacking of two-dimensional (2D) porous membranes. Punching forces were experimentally measured, and finite element modeling of the punching process was validated by comparing punching force results. Holes of nominal diameter of 200 μm were punched in PCL films of two different thicknesses: 40 μm and 70 μm. Die clearances used for holes in 40 μm thick films were 15.0%, 30.0%, and 45.0%. Die clearances used for holes in 70 μm films were 8.6%, 17.1%, and 25.7%. All holes were punched while the PCL film was in thermal equilibrium with a bath of boiling liquid nitrogen. Punching forces were analyzed to study the effect of die clearance and film thickness. A 3D finite element simulation of the punching process was done using deform 3d software. Cryogenic material properties of PCL used in the simulation were determined experimentally. It was concluded that finite element simulation for the cryogenic micropunching process can be used to predict peak punching forces with reasonable accuracy, which is a key factor to be considered while designing the punching dies. The finite element simulations did not predict an optimal die clearance to minimize peak punching force. However, the measured peak punching forces for 70 μm thick film seem to favor the smallest die clearance to minimize peak punching force.
    • Download: (1.083Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effect of Die Clearance on Peak Punching Force During Cryogenic Micropunching of Polycaprolactone

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277960
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorSagar, Amrit
    contributor authorNehme, Christopher
    contributor authorSaigal, Anil
    contributor authorJames, Thomas P.
    date accessioned2022-02-05T22:40:42Z
    date available2022-02-05T22:40:42Z
    date copyright12/10/2020 12:00:00 AM
    date issued2020
    identifier issn2572-7958
    identifier otherjesmdt_004_01_011004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277960
    description abstractMicroscale holes were punched at cryogenic conditions in polycaprolactone (PCL) membranes to create synthetic three-dimensional (3D) tissue scaffolds through multilayer stacking of two-dimensional (2D) porous membranes. Punching forces were experimentally measured, and finite element modeling of the punching process was validated by comparing punching force results. Holes of nominal diameter of 200 μm were punched in PCL films of two different thicknesses: 40 μm and 70 μm. Die clearances used for holes in 40 μm thick films were 15.0%, 30.0%, and 45.0%. Die clearances used for holes in 70 μm films were 8.6%, 17.1%, and 25.7%. All holes were punched while the PCL film was in thermal equilibrium with a bath of boiling liquid nitrogen. Punching forces were analyzed to study the effect of die clearance and film thickness. A 3D finite element simulation of the punching process was done using deform 3d software. Cryogenic material properties of PCL used in the simulation were determined experimentally. It was concluded that finite element simulation for the cryogenic micropunching process can be used to predict peak punching forces with reasonable accuracy, which is a key factor to be considered while designing the punching dies. The finite element simulations did not predict an optimal die clearance to minimize peak punching force. However, the measured peak punching forces for 70 μm thick film seem to favor the smallest die clearance to minimize peak punching force.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffect of Die Clearance on Peak Punching Force During Cryogenic Micropunching of Polycaprolactone
    typeJournal Paper
    journal volume4
    journal issue1
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4049106
    journal fristpage011004-1
    journal lastpage011004-6
    page6
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2020:;volume( 004 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian