On the Reliability of Suction Measurements for Skin CharacterizationSource: Journal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 002::page 021002-1DOI: 10.1115/1.4047661Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: in vivo skin characterization methods were shown to be useful in the detection of microstructural alterations of the dermis due to skin diseases. Specifically, the diagnostic potential of skin suction has been widely explored, yet measurement uncertainties prevented so far its application in clinical assessment. In this work, we analyze specific factors influencing the reliability of suction measurements. We recently proposed a novel suction device, called Nimble, addressing the limitations of existing instruments, and applied it in clinical trials quantifying mechanical differences between healthy skin and scars. Measurements were performed with the commercial device Cutometer and with the new device. A set of new suction measurements was carried out on scar tissue and healthy skin, and FE-based inverse analysis was applied to determine corresponding parameters of a hyperelastic-viscoelastic material model. FE simulations were used to rationalize differences between suction protocols and to analyze specific factors influencing the measurement procedure. Tissue stiffness obtained from Cutometer measurements was significantly higher compared to the one from Nimble measurements, which was shown to be associated with the higher deformation levels in the Cutometer and the nonlinear mechanical response of skin. The effect of the contact force exerted on skin during suction measurements was quantified, along with an analysis of the effectiveness of a corresponding correction procedure. Parametric studies demonstrated the inherently higher sensitivity of displacement- over load-controlled suction measurements, thus rationalizing the superior ability of the Nimble to distinguish between tissues.
|
Collections
Show full item record
| contributor author | Mueller, Bettina | |
| contributor author | Elrod, Julia | |
| contributor author | Distler, Oliver | |
| contributor author | Schiestl, Clemens | |
| contributor author | Mazza, Edoardo | |
| date accessioned | 2022-02-05T22:18:51Z | |
| date available | 2022-02-05T22:18:51Z | |
| date copyright | 10/8/2020 12:00:00 AM | |
| date issued | 2020 | |
| identifier issn | 0148-0731 | |
| identifier other | bio_143_02_021002.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4277325 | |
| description abstract | in vivo skin characterization methods were shown to be useful in the detection of microstructural alterations of the dermis due to skin diseases. Specifically, the diagnostic potential of skin suction has been widely explored, yet measurement uncertainties prevented so far its application in clinical assessment. In this work, we analyze specific factors influencing the reliability of suction measurements. We recently proposed a novel suction device, called Nimble, addressing the limitations of existing instruments, and applied it in clinical trials quantifying mechanical differences between healthy skin and scars. Measurements were performed with the commercial device Cutometer and with the new device. A set of new suction measurements was carried out on scar tissue and healthy skin, and FE-based inverse analysis was applied to determine corresponding parameters of a hyperelastic-viscoelastic material model. FE simulations were used to rationalize differences between suction protocols and to analyze specific factors influencing the measurement procedure. Tissue stiffness obtained from Cutometer measurements was significantly higher compared to the one from Nimble measurements, which was shown to be associated with the higher deformation levels in the Cutometer and the nonlinear mechanical response of skin. The effect of the contact force exerted on skin during suction measurements was quantified, along with an analysis of the effectiveness of a corresponding correction procedure. Parametric studies demonstrated the inherently higher sensitivity of displacement- over load-controlled suction measurements, thus rationalizing the superior ability of the Nimble to distinguish between tissues. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | On the Reliability of Suction Measurements for Skin Characterization | |
| type | Journal Paper | |
| journal volume | 143 | |
| journal issue | 2 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4047661 | |
| journal fristpage | 021002-1 | |
| journal lastpage | 021002-10 | |
| page | 10 | |
| tree | Journal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 002 | |
| contenttype | Fulltext |