Show simple item record

contributor authorMueller, Bettina
contributor authorElrod, Julia
contributor authorDistler, Oliver
contributor authorSchiestl, Clemens
contributor authorMazza, Edoardo
date accessioned2022-02-05T22:18:51Z
date available2022-02-05T22:18:51Z
date copyright10/8/2020 12:00:00 AM
date issued2020
identifier issn0148-0731
identifier otherbio_143_02_021002.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277325
description abstractin vivo skin characterization methods were shown to be useful in the detection of microstructural alterations of the dermis due to skin diseases. Specifically, the diagnostic potential of skin suction has been widely explored, yet measurement uncertainties prevented so far its application in clinical assessment. In this work, we analyze specific factors influencing the reliability of suction measurements. We recently proposed a novel suction device, called Nimble, addressing the limitations of existing instruments, and applied it in clinical trials quantifying mechanical differences between healthy skin and scars. Measurements were performed with the commercial device Cutometer and with the new device. A set of new suction measurements was carried out on scar tissue and healthy skin, and FE-based inverse analysis was applied to determine corresponding parameters of a hyperelastic-viscoelastic material model. FE simulations were used to rationalize differences between suction protocols and to analyze specific factors influencing the measurement procedure. Tissue stiffness obtained from Cutometer measurements was significantly higher compared to the one from Nimble measurements, which was shown to be associated with the higher deformation levels in the Cutometer and the nonlinear mechanical response of skin. The effect of the contact force exerted on skin during suction measurements was quantified, along with an analysis of the effectiveness of a corresponding correction procedure. Parametric studies demonstrated the inherently higher sensitivity of displacement- over load-controlled suction measurements, thus rationalizing the superior ability of the Nimble to distinguish between tissues.
publisherThe American Society of Mechanical Engineers (ASME)
titleOn the Reliability of Suction Measurements for Skin Characterization
typeJournal Paper
journal volume143
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4047661
journal fristpage021002-1
journal lastpage021002-10
page10
treeJournal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record