    Noninvasive Method to Measure Thermal Energy Flow Rate in a Pipe

    Source: Journal of Thermal Science and Engineering Applications:;2020:;volume( 013 ):;issue: 003::page 031024-1
    Author:
    Alanazi, Mohammed A.
    ,
    Diller, Thomas E.
    DOI: 10.1115/1.4048676
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A noninvasive, thermal energy flowrate sensor based on a combination of heat flux and temperature measurements is developed for measuring the volume flowrate and the fluid temperature in a pipe. The sensor is covered by a thin-film heater and clamped onto the outer surface of the pipe. Two types of thin-film thermocouple elements are compared to minimize the thermal contact resistance R″ between the thermocouple and the surface of the pipe. A thin, flexible thermopile heat flux sensor (PHFS) is mounted over the thermocouples. A one-dimensional transient thermal model is applied before and during activation of the external heater to provide estimates of the fluid heat transfer coefficient h. The results are correlated with the volume flowrate Q and the fluid temperature Twc. Several different parameter estimation codes are used to estimate the optimal parameters by using the minimum root-mean-square (rms) error between the analytical and experimental sensor temperature values. The experiments are completed over a range of volume flowrates—1.3 gallons/min to 14.5 gallons/min. Encouraging measurement results give good correlation, repeatability, and sensitivity between the heat transfer coefficient h and the volume flowrate Q with an accurate estimation of the fluid temperature Twc. The resulting noninvasive thermal energy flowrate sensor can be used to estimate the volume flowrate and the fluid temperature in a variety of applications.
    • Download: (1.215Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Noninvasive Method to Measure Thermal Energy Flow Rate in a Pipe

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276860
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorAlanazi, Mohammed A.
    contributor authorDiller, Thomas E.
    date accessioned2022-02-05T22:04:32Z
    date available2022-02-05T22:04:32Z
    date copyright11/6/2020 12:00:00 AM
    date issued2020
    identifier issn1948-5085
    identifier othertsea_13_3_031024.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276860
    description abstractA noninvasive, thermal energy flowrate sensor based on a combination of heat flux and temperature measurements is developed for measuring the volume flowrate and the fluid temperature in a pipe. The sensor is covered by a thin-film heater and clamped onto the outer surface of the pipe. Two types of thin-film thermocouple elements are compared to minimize the thermal contact resistance R″ between the thermocouple and the surface of the pipe. A thin, flexible thermopile heat flux sensor (PHFS) is mounted over the thermocouples. A one-dimensional transient thermal model is applied before and during activation of the external heater to provide estimates of the fluid heat transfer coefficient h. The results are correlated with the volume flowrate Q and the fluid temperature Twc. Several different parameter estimation codes are used to estimate the optimal parameters by using the minimum root-mean-square (rms) error between the analytical and experimental sensor temperature values. The experiments are completed over a range of volume flowrates—1.3 gallons/min to 14.5 gallons/min. Encouraging measurement results give good correlation, repeatability, and sensitivity between the heat transfer coefficient h and the volume flowrate Q with an accurate estimation of the fluid temperature Twc. The resulting noninvasive thermal energy flowrate sensor can be used to estimate the volume flowrate and the fluid temperature in a variety of applications.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNoninvasive Method to Measure Thermal Energy Flow Rate in a Pipe
    typeJournal Paper
    journal volume13
    journal issue3
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4048676
    journal fristpage031024-1
    journal lastpage031024-10
    page10
    treeJournal of Thermal Science and Engineering Applications:;2020:;volume( 013 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian