    Model and Experimental Verification of the Dynamic Forced Performance of a Tightly Sealed Squeeze Film Damper Supplied With a Bubbly Mixture

    Source: Journal of Engineering for Gas Turbines and Power:;2020:;volume( 142 ):;issue: 001::page 011023-1
    Author:
    San Andrés, Luis
    ,
    Koo, Bonjin
    DOI: 10.1115/1.4044994
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Practice and experiments with squeeze film dampers (SFDs) sealed with piston rings (PRs) show the lubricant exits through the PR slit, i.e., the gap made by the PR abutted ends when installed, forced as a jet during the portion of a rotor whirl cycle generating a positive squeeze film pressure. In the other portion of a whirl cycle, a subambient dynamic pressure ingests air into the film that mixes with the lubricant to produce a bubbly mixture. To reduce persistent air ingestion, commercial air breathing engines utilizing PRSFDs demand of a sufficiently large lubricant supply pressure (Ps), and hence a larger flow rate that is proportional to the journal squeeze velocity (vs = amplitude r × frequency of motion ω). The stringent requirement clearly limits the applicability and usefulness of SFDs. This paper presents a computational physics model for a sealed-end SFD operating with a mixture and delivers predictions benchmarked against profuse laboratory test data. The model implements a Reynolds equation adapted for a homogeneous bubbly mixture, includes temporal fluid inertia effects, and uses physics-based inlet and outlet lubricant conditions through feed holes and PR slit, respectively. In the experiments for model validation, a SFD damper, 127 mm in diameter D, film land length L = 25.4 mm (L/D = 0.2), and radial clearance c = 0.371 mm, is supplied with an air in ISO VG2 oil bubbly mixture of known gas volume fraction (GVF), zero (pure oil) to 50% in steps of 10%. The mixture supply pressure varies from Ps = 2.06 bar-g (30 psig) to 6.20 bar-g (90 psig). Located in grooves at the top and bottom of the journal, a PR and an O-ring (OR) seal the film land. The OR does not allow any oil leakage or air ingestion; hence, the supplied mixture discharges through the PR slit into a vessel submerged within a large volume of lubricant. Dynamic load tests with a single frequency ω, varying from 10 Hz to 60 Hz, produce circular centered orbits (CCO) with amplitude r = 0.2c. The measurements record the exerted forces and journal motions and an analysis delivers force coefficients, damping and inertia, representative of the exerted frequency range. The model predicts the pressure field and evolution of the GVF within the film land and, in a simulated process replicating the experimental procedure, delivers representative force coefficients. For all Ps conditions, both predictions and tests show the SFD added mass coefficients significantly decrease as the inlet GVF (βs) increases. The experimentally derived damping coefficients do not show a significant change, except for tests with the largest concentration of air (βs = 0.5). The predicted damping differs by 10% with the test derived coefficient which does not readily decrease as the inlet GVF (βs) increases. The added mass coefficients, test and predicted, decrease with βs, both being impervious to the magnitude of supply pressure. The test PRSFD shows a quadrature stiffness due to the sliding friction between the PR being pushed against the journal. An increase in supply pressure exacerbates this unique stiffness that may impair the action of the squeeze film to dissipate mechanical energy. The comprehensive test results, first of their kind, demonstrate that accurate modeling of SFDs operating with air ingestion remains difficult as the flow process and the paths of its major components (air and liquid) are rather complex.
    • Download: (5.069Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Model and Experimental Verification of the Dynamic Forced Performance of a Tightly Sealed Squeeze Film Damper Supplied With a Bubbly Mixture

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276052
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorSan Andrés, Luis
    contributor authorKoo, Bonjin
    date accessioned2022-02-04T23:04:37Z
    date available2022-02-04T23:04:37Z
    date copyright1/1/2020 12:00:00 AM
    date issued2020
    identifier issn0742-4795
    identifier othergtp_142_01_011023.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276052
    description abstractPractice and experiments with squeeze film dampers (SFDs) sealed with piston rings (PRs) show the lubricant exits through the PR slit, i.e., the gap made by the PR abutted ends when installed, forced as a jet during the portion of a rotor whirl cycle generating a positive squeeze film pressure. In the other portion of a whirl cycle, a subambient dynamic pressure ingests air into the film that mixes with the lubricant to produce a bubbly mixture. To reduce persistent air ingestion, commercial air breathing engines utilizing PRSFDs demand of a sufficiently large lubricant supply pressure (Ps), and hence a larger flow rate that is proportional to the journal squeeze velocity (vs = amplitude r × frequency of motion ω). The stringent requirement clearly limits the applicability and usefulness of SFDs. This paper presents a computational physics model for a sealed-end SFD operating with a mixture and delivers predictions benchmarked against profuse laboratory test data. The model implements a Reynolds equation adapted for a homogeneous bubbly mixture, includes temporal fluid inertia effects, and uses physics-based inlet and outlet lubricant conditions through feed holes and PR slit, respectively. In the experiments for model validation, a SFD damper, 127 mm in diameter D, film land length L = 25.4 mm (L/D = 0.2), and radial clearance c = 0.371 mm, is supplied with an air in ISO VG2 oil bubbly mixture of known gas volume fraction (GVF), zero (pure oil) to 50% in steps of 10%. The mixture supply pressure varies from Ps = 2.06 bar-g (30 psig) to 6.20 bar-g (90 psig). Located in grooves at the top and bottom of the journal, a PR and an O-ring (OR) seal the film land. The OR does not allow any oil leakage or air ingestion; hence, the supplied mixture discharges through the PR slit into a vessel submerged within a large volume of lubricant. Dynamic load tests with a single frequency ω, varying from 10 Hz to 60 Hz, produce circular centered orbits (CCO) with amplitude r = 0.2c. The measurements record the exerted forces and journal motions and an analysis delivers force coefficients, damping and inertia, representative of the exerted frequency range. The model predicts the pressure field and evolution of the GVF within the film land and, in a simulated process replicating the experimental procedure, delivers representative force coefficients. For all Ps conditions, both predictions and tests show the SFD added mass coefficients significantly decrease as the inlet GVF (βs) increases. The experimentally derived damping coefficients do not show a significant change, except for tests with the largest concentration of air (βs = 0.5). The predicted damping differs by 10% with the test derived coefficient which does not readily decrease as the inlet GVF (βs) increases. The added mass coefficients, test and predicted, decrease with βs, both being impervious to the magnitude of supply pressure. The test PRSFD shows a quadrature stiffness due to the sliding friction between the PR being pushed against the journal. An increase in supply pressure exacerbates this unique stiffness that may impair the action of the squeeze film to dissipate mechanical energy. The comprehensive test results, first of their kind, demonstrate that accurate modeling of SFDs operating with air ingestion remains difficult as the flow process and the paths of its major components (air and liquid) are rather complex.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleModel and Experimental Verification of the Dynamic Forced Performance of a Tightly Sealed Squeeze Film Damper Supplied With a Bubbly Mixture
    typeJournal Paper
    journal volume142
    journal issue1
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4044994
    journal fristpage011023-1
    journal lastpage011023-12
    page12
    treeJournal of Engineering for Gas Turbines and Power:;2020:;volume( 142 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian