    High Amplitude Combustion Instabilities in an Annular Combustor Inducing Pressure Field Deformation and Flame Blow Off

    Source: Journal of Engineering for Gas Turbines and Power:;2020:;volume( 142 ):;issue: 001::page 011016-1
    Author:
    Vignat, Guillaume
    ,
    Durox, Daniel
    ,
    Renaud, Antoine
    ,
    Candel, Sébastien
    DOI: 10.1115/1.4045515
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This article reports experiments carried out in the laboratory scale annular combustor MICCA-spray equipped with multiple swirling spray injectors. The experimental setup consists in an air plenum connected to a combustion chamber formed by two concentric cylindrical quartz tubes, allowing full optical access to the flames. A new injection system is introduced and characterized. For a wide range of operating conditions, strong combustion instabilities are observed, but the focus of this article is placed on very high amplitude combustion instabilities coupled by a standing azimuthal mode. New results are obtained using a higher order reconstruction method for the pressure field: its shape is shown to be modified during high amplitude oscillation, leading to asymmetries of the pressure distribution in the system. Flame blow off occurs near the pressure nodal line when a critical level of oscillation is reached. A method is proposed to reconstruct the acoustic velocity field just before blow off occurs and in this way determine the blow off threshold. It is found that the pressure distribution, velocity field, and blow off pattern become asymmetric as the amplitude of oscillation increases and that this process is accompanied by a rapid shift in frequency of oscillation. Another notable result is that the heat release rate in the flames on the same side of the nodal line is not perfectly in phase and that the phase differences become larger as the amplitude of oscillation increases.
    • Download: (5.267Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      High Amplitude Combustion Instabilities in an Annular Combustor Inducing Pressure Field Deformation and Flame Blow Off

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4275811
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorVignat, Guillaume
    contributor authorDurox, Daniel
    contributor authorRenaud, Antoine
    contributor authorCandel, Sébastien
    date accessioned2022-02-04T22:58:09Z
    date available2022-02-04T22:58:09Z
    date copyright1/1/2020 12:00:00 AM
    date issued2020
    identifier issn0742-4795
    identifier othergtp_142_01_011016.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275811
    description abstractThis article reports experiments carried out in the laboratory scale annular combustor MICCA-spray equipped with multiple swirling spray injectors. The experimental setup consists in an air plenum connected to a combustion chamber formed by two concentric cylindrical quartz tubes, allowing full optical access to the flames. A new injection system is introduced and characterized. For a wide range of operating conditions, strong combustion instabilities are observed, but the focus of this article is placed on very high amplitude combustion instabilities coupled by a standing azimuthal mode. New results are obtained using a higher order reconstruction method for the pressure field: its shape is shown to be modified during high amplitude oscillation, leading to asymmetries of the pressure distribution in the system. Flame blow off occurs near the pressure nodal line when a critical level of oscillation is reached. A method is proposed to reconstruct the acoustic velocity field just before blow off occurs and in this way determine the blow off threshold. It is found that the pressure distribution, velocity field, and blow off pattern become asymmetric as the amplitude of oscillation increases and that this process is accompanied by a rapid shift in frequency of oscillation. Another notable result is that the heat release rate in the flames on the same side of the nodal line is not perfectly in phase and that the phase differences become larger as the amplitude of oscillation increases.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHigh Amplitude Combustion Instabilities in an Annular Combustor Inducing Pressure Field Deformation and Flame Blow Off
    typeJournal Paper
    journal volume142
    journal issue1
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4045515
    journal fristpage011016-1
    journal lastpage011016-11
    page11
    treeJournal of Engineering for Gas Turbines and Power:;2020:;volume( 142 ):;issue: 001
    contenttypeFulltext