YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Improved Treatment of Postpartum Hemorrhage: Design, Development, and Bench-Top Validation of a Reusable Intrauterine Tamponade Device for Low-Resource Settings

    Source: Journal of Medical Devices:;2020:;volume( 014 ):;issue: 001
    Author:
    Hu, Katherine
    ,
    Lapinski, Maya M.
    ,
    Mischler, Gavin
    ,
    Allen, Robert H.
    ,
    Manbachi, Amir
    ,
    Seay, Rachel Chan
    DOI: 10.1115/1.4045965
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Postpartum hemorrhage (PPH) is the leading cause of maternal mortality worldwide, and effective interventions for addressing PPH are urgently needed. Uterine balloon tamponade (UBT) is a technique to control PPH. Commercially available UBT devices are expensive and frequently require imaging technology to ensure placement. Condom-catheter uterine tamponade (C-UBT) is a technique appropriate for low-resource settings. Testing of the C-UBT is needed to better understand and optimize this technique for use in a variety of clinical settings including low-resource contexts. We describe here the design, development, and bench-top validation of a reusable C-UBT device optimized for low-resource settings. The device was tested in three differently sized uterine models using a variety of condom balloon configurations. Intrauterine wall pressure application was measured to evaluate the device capacity to apply pressure of at least 90 mmHg, estimating the mean arterial pressure within the uterine vasculature. Bench-top experimental validation of pressure exerted in uterine models demonstrated the device's capability of reaching hemostatic pressure in uterine volumes ranging from 170 to 1740 mL. Device adaptability and versatility were shown through its ability to reach the target pressure of 90 mmHg in different uterine sizes by varying balloon parameters, including condom thickness and condom configuration. The results of this study show the potential of a low-cost, reusable C-UBT device optimized to treat PPH in a variety of clinical settings, including low-resource contexts.
    • Download: (984.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Improved Treatment of Postpartum Hemorrhage: Design, Development, and Bench-Top Validation of a Reusable Intrauterine Tamponade Device for Low-Resource Settings

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4274340
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorHu, Katherine
    contributor authorLapinski, Maya M.
    contributor authorMischler, Gavin
    contributor authorAllen, Robert H.
    contributor authorManbachi, Amir
    contributor authorSeay, Rachel Chan
    date accessioned2022-02-04T14:46:25Z
    date available2022-02-04T14:46:25Z
    date copyright2020/01/31/
    date issued2020
    identifier issn1932-6181
    identifier othermed_014_01_014503.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274340
    description abstractPostpartum hemorrhage (PPH) is the leading cause of maternal mortality worldwide, and effective interventions for addressing PPH are urgently needed. Uterine balloon tamponade (UBT) is a technique to control PPH. Commercially available UBT devices are expensive and frequently require imaging technology to ensure placement. Condom-catheter uterine tamponade (C-UBT) is a technique appropriate for low-resource settings. Testing of the C-UBT is needed to better understand and optimize this technique for use in a variety of clinical settings including low-resource contexts. We describe here the design, development, and bench-top validation of a reusable C-UBT device optimized for low-resource settings. The device was tested in three differently sized uterine models using a variety of condom balloon configurations. Intrauterine wall pressure application was measured to evaluate the device capacity to apply pressure of at least 90 mmHg, estimating the mean arterial pressure within the uterine vasculature. Bench-top experimental validation of pressure exerted in uterine models demonstrated the device's capability of reaching hemostatic pressure in uterine volumes ranging from 170 to 1740 mL. Device adaptability and versatility were shown through its ability to reach the target pressure of 90 mmHg in different uterine sizes by varying balloon parameters, including condom thickness and condom configuration. The results of this study show the potential of a low-cost, reusable C-UBT device optimized to treat PPH in a variety of clinical settings, including low-resource contexts.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleImproved Treatment of Postpartum Hemorrhage: Design, Development, and Bench-Top Validation of a Reusable Intrauterine Tamponade Device for Low-Resource Settings
    typeJournal Paper
    journal volume14
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4045965
    page14503
    treeJournal of Medical Devices:;2020:;volume( 014 ):;issue: 001
    contenttypeFulltext