Show simple item record

contributor authorHu, Katherine
contributor authorLapinski, Maya M.
contributor authorMischler, Gavin
contributor authorAllen, Robert H.
contributor authorManbachi, Amir
contributor authorSeay, Rachel Chan
date accessioned2022-02-04T14:46:25Z
date available2022-02-04T14:46:25Z
date copyright2020/01/31/
date issued2020
identifier issn1932-6181
identifier othermed_014_01_014503.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274340
description abstractPostpartum hemorrhage (PPH) is the leading cause of maternal mortality worldwide, and effective interventions for addressing PPH are urgently needed. Uterine balloon tamponade (UBT) is a technique to control PPH. Commercially available UBT devices are expensive and frequently require imaging technology to ensure placement. Condom-catheter uterine tamponade (C-UBT) is a technique appropriate for low-resource settings. Testing of the C-UBT is needed to better understand and optimize this technique for use in a variety of clinical settings including low-resource contexts. We describe here the design, development, and bench-top validation of a reusable C-UBT device optimized for low-resource settings. The device was tested in three differently sized uterine models using a variety of condom balloon configurations. Intrauterine wall pressure application was measured to evaluate the device capacity to apply pressure of at least 90 mmHg, estimating the mean arterial pressure within the uterine vasculature. Bench-top experimental validation of pressure exerted in uterine models demonstrated the device's capability of reaching hemostatic pressure in uterine volumes ranging from 170 to 1740 mL. Device adaptability and versatility were shown through its ability to reach the target pressure of 90 mmHg in different uterine sizes by varying balloon parameters, including condom thickness and condom configuration. The results of this study show the potential of a low-cost, reusable C-UBT device optimized to treat PPH in a variety of clinical settings, including low-resource contexts.
publisherThe American Society of Mechanical Engineers (ASME)
titleImproved Treatment of Postpartum Hemorrhage: Design, Development, and Bench-Top Validation of a Reusable Intrauterine Tamponade Device for Low-Resource Settings
typeJournal Paper
journal volume14
journal issue1
journal titleJournal of Medical Devices
identifier doi10.1115/1.4045965
page14503
treeJournal of Medical Devices:;2020:;volume( 014 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record