Effect of Filling Ratio and Tilt Angle on the Performance of a Mini-Loop ThermosyphonSource: Journal of Thermal Science and Engineering Applications:;2019:;volume( 011 ):;issue: 006::page 61013DOI: 10.1115/1.4043464Publisher: American Society of Mechanical Engineers (ASME)
Abstract: The thermal behavior of a compact mini-loop thermosyphon is experimentally studied at different filling ratios (20%, 30%, 40%, 50%, and 70%) and tilt angles (0 deg, 30 deg, 45 deg, 60 deg, and 90 deg) for the heat loads of 20–300 W using distilled water as the heat pipe fluid. The presence of microfins at the evaporator results in an average decrease of 37.4% and 15.3% in thermal resistance and evaporator wall temperature, respectively, compared with the evaporator with a plain surface. Both filling ratio (FR) and tilt angle influence the heat transfer performance significantly, and the best performance of the mini-loop thermosyphon is obtained at their optimum values. The thermal resistance and thermal efficiency values lie in the ranges of 0.73–0.076 K/W and 65–88.3% for different filling ratios and tilt angles. Similarly, evaporator heat transfer coefficient and evaporator wall temperature show significant variation with changes in filling ratio and tilt angle. A combination of the optimum filling ratio and tilt angle shows a lowest thermal resistance of 0.076 K/W and a highest evaporator wall temperature of 68.6 °C, which are obtained at 300 W. The experimental results recommend the use of mini-loop thermosyphon at an optimum filling ratio for electronics cooling applications, which have a heat dissipation of 20–300 W.
|
Show full item record
contributor author | Tharayil, Trijo | |
contributor author | Gitty, Neha | |
contributor author | Asirvatham, Lazarus Godson | |
contributor author | Wongwises, Somchai | |
date accessioned | 2019-09-18T09:08:04Z | |
date available | 2019-09-18T09:08:04Z | |
date copyright | 5/20/2019 12:00:00 AM | |
date issued | 2019 | |
identifier issn | 1948-5085 | |
identifier other | tsea_11_6_061013 | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4259252 | |
description abstract | The thermal behavior of a compact mini-loop thermosyphon is experimentally studied at different filling ratios (20%, 30%, 40%, 50%, and 70%) and tilt angles (0 deg, 30 deg, 45 deg, 60 deg, and 90 deg) for the heat loads of 20–300 W using distilled water as the heat pipe fluid. The presence of microfins at the evaporator results in an average decrease of 37.4% and 15.3% in thermal resistance and evaporator wall temperature, respectively, compared with the evaporator with a plain surface. Both filling ratio (FR) and tilt angle influence the heat transfer performance significantly, and the best performance of the mini-loop thermosyphon is obtained at their optimum values. The thermal resistance and thermal efficiency values lie in the ranges of 0.73–0.076 K/W and 65–88.3% for different filling ratios and tilt angles. Similarly, evaporator heat transfer coefficient and evaporator wall temperature show significant variation with changes in filling ratio and tilt angle. A combination of the optimum filling ratio and tilt angle shows a lowest thermal resistance of 0.076 K/W and a highest evaporator wall temperature of 68.6 °C, which are obtained at 300 W. The experimental results recommend the use of mini-loop thermosyphon at an optimum filling ratio for electronics cooling applications, which have a heat dissipation of 20–300 W. | |
publisher | American Society of Mechanical Engineers (ASME) | |
title | Effect of Filling Ratio and Tilt Angle on the Performance of a Mini-Loop Thermosyphon | |
type | Journal Paper | |
journal volume | 11 | |
journal issue | 6 | |
journal title | Journal of Thermal Science and Engineering Applications | |
identifier doi | 10.1115/1.4043464 | |
journal fristpage | 61013 | |
journal lastpage | 061013-11 | |
tree | Journal of Thermal Science and Engineering Applications:;2019:;volume( 011 ):;issue: 006 | |
contenttype | Fulltext |