    Archive

    Measurement of Frictional Properties of Aortic Stent Grafts and Their Delivery Systems

    Source: Journal of Medical Devices:;2019:;volume( 013 ):;issue: 002::page 21008
    Author:
    Chen, Tianhao
    ,
    Lancaster, Michael
    ,
    Lin, Dawn S. Y.
    ,
    Doyle, Matthew G.
    ,
    Forbes, Thomas L.
    ,
    Amon, Cristina H.
    DOI: 10.1115/1.4043292
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: Stent grafts are medical devices used to treat abdominal aortic aneurysms (AAAs) in endovascular aneurysm repair (EVAR). Computational and experimental models have been developed to study stent graft delivery and deployment during EVAR; however, frictional properties have not been taken into account in most previous studies. The objective of this study was to determine the coefficients of friction of three commercially available stent grafts (Cook Zenith, Medtronic Endurant, and Vascutek Anaconda), their delivery sheaths, a porcine aorta, and two mock arterial materials. Stent grafts were obtained and separated into stents, graft fabric, and sheaths. Using a custom-made friction measurement apparatus, the coefficients of friction were measured between five material pairs: (i) the stents and inner surface of the sheath, (ii) the graft fabric and inner surface of the sheath, (iii) the outer surface of the sheath and a porcine aorta, (iv) the outer surface of the sheath and three different polyvinyl alcohol (PVA) cryogels, and (v) the outer surface of the sheath and a polydimethylsiloxane (PDMS) sheet. The results show that the coefficients of friction between the graft fabric and the sheath were higher than those between the stents and the sheath. The PVA cryogels showed more comparable frictional properties to the porcine aorta than did the PDMS sheet, suggesting that PVA cryogels provide a more accurate approximation for the in vivo frictional properties. These results can be used to improve the accuracy of computational models for stent graft delivery and deployment and to select appropriate materials for vascular phantoms.
    • Download: (4.234Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Measurement of Frictional Properties of Aortic Stent Grafts and Their Delivery Systems

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4259078
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorChen, Tianhao
    contributor authorLancaster, Michael
    contributor authorLin, Dawn S. Y.
    contributor authorDoyle, Matthew G.
    contributor authorForbes, Thomas L.
    contributor authorAmon, Cristina H.
    date accessioned2019-09-18T09:07:10Z
    date available2019-09-18T09:07:10Z
    date copyright4/11/2019 12:00:00 AM
    date issued2019
    identifier issn1932-6181
    identifier othermed_013_02_021008
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259078
    description abstractStent grafts are medical devices used to treat abdominal aortic aneurysms (AAAs) in endovascular aneurysm repair (EVAR). Computational and experimental models have been developed to study stent graft delivery and deployment during EVAR; however, frictional properties have not been taken into account in most previous studies. The objective of this study was to determine the coefficients of friction of three commercially available stent grafts (Cook Zenith, Medtronic Endurant, and Vascutek Anaconda), their delivery sheaths, a porcine aorta, and two mock arterial materials. Stent grafts were obtained and separated into stents, graft fabric, and sheaths. Using a custom-made friction measurement apparatus, the coefficients of friction were measured between five material pairs: (i) the stents and inner surface of the sheath, (ii) the graft fabric and inner surface of the sheath, (iii) the outer surface of the sheath and a porcine aorta, (iv) the outer surface of the sheath and three different polyvinyl alcohol (PVA) cryogels, and (v) the outer surface of the sheath and a polydimethylsiloxane (PDMS) sheet. The results show that the coefficients of friction between the graft fabric and the sheath were higher than those between the stents and the sheath. The PVA cryogels showed more comparable frictional properties to the porcine aorta than did the PDMS sheet, suggesting that PVA cryogels provide a more accurate approximation for the in vivo frictional properties. These results can be used to improve the accuracy of computational models for stent graft delivery and deployment and to select appropriate materials for vascular phantoms.
    publisherAmerican Society of Mechanical Engineers (ASME)
    titleMeasurement of Frictional Properties of Aortic Stent Grafts and Their Delivery Systems
    typeJournal Paper
    journal volume13
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4043292
    journal fristpage21008
    journal lastpage021008-9
    treeJournal of Medical Devices:;2019:;volume( 013 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian