description abstractStent grafts are medical devices used to treat abdominal aortic aneurysms (AAAs) in endovascular aneurysm repair (EVAR). Computational and experimental models have been developed to study stent graft delivery and deployment during EVAR; however, frictional properties have not been taken into account in most previous studies. The objective of this study was to determine the coefficients of friction of three commercially available stent grafts (Cook Zenith, Medtronic Endurant, and Vascutek Anaconda), their delivery sheaths, a porcine aorta, and two mock arterial materials. Stent grafts were obtained and separated into stents, graft fabric, and sheaths. Using a custom-made friction measurement apparatus, the coefficients of friction were measured between five material pairs: (i) the stents and inner surface of the sheath, (ii) the graft fabric and inner surface of the sheath, (iii) the outer surface of the sheath and a porcine aorta, (iv) the outer surface of the sheath and three different polyvinyl alcohol (PVA) cryogels, and (v) the outer surface of the sheath and a polydimethylsiloxane (PDMS) sheet. The results show that the coefficients of friction between the graft fabric and the sheath were higher than those between the stents and the sheath. The PVA cryogels showed more comparable frictional properties to the porcine aorta than did the PDMS sheet, suggesting that PVA cryogels provide a more accurate approximation for the in vivo frictional properties. These results can be used to improve the accuracy of computational models for stent graft delivery and deployment and to select appropriate materials for vascular phantoms.
publisherAmerican Society of Mechanical Engineers (ASME)
titleMeasurement of Frictional Properties of Aortic Stent Grafts and Their Delivery Systems
typeJournal Paper
journal volume13
journal issue2
journal titleJournal of Medical Devices
identifier doi10.1115/1.4043292
journal fristpage21008
journal lastpage021008-9
treeJournal of Medical Devices:;2019:;volume( 013 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record