    Archive

    Investigation on Heat Transfer Performance and Flow Resistance Characteristics in Finned-Tube Heat Exchangers With Different Vortex Generator Positions

    Source: Journal of Heat Transfer:;2019:;volume( 141 ):;issue: 009::page 91804
    Author:
    Qiang, Wang
    ,
    Zuoqin, Qian
    ,
    Junlin, Cheng
    ,
    Jie, Ren
    ,
    Weilong, Huang
    DOI: 10.1115/1.4042008
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: The numerical simulation was carried out to investigate mechanism of the heat transfer enhancement in the fin-and-tube heat exchangers. As known, the vortex generators (VGs) were widely used to improve the thermal performance with bad flow resistance characteristics and led to bad comprehensive performance. This paper aims to expound the mechanism of thermal hydraulic characteristics and explore the effect of VGs position on the comprehensive performance. Three types of fins (type 1, type 2, and type 3) were discussed in this paper. The j factor, f factor, and performance evaluation (PEC) of three types of VGs in different positions were discussed and compared. Based on the numerical results, a detailed description of the effect of three types of VGs on the heat transfer performance and flow resistance characteristics was presented at different Reynolds number in the range between 1300 and 2000. In addition, local velocity distribution, local temperature distribution, and local pressure drop distribution were analyzed and discussed. And the effect of VG angle on the thermal performance and flow resistance was presented. It can be concluded that the main heat transfer occurred in the region before the tube, and the wake region behind the tube was harmful to improve the thermal performance and reduce the flow resistance. Besides, VG in the wake region was obviously beneficial to the enhancement of the thermal performance with less energy loss.
    • Download: (2.462Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Investigation on Heat Transfer Performance and Flow Resistance Characteristics in Finned-Tube Heat Exchangers With Different Vortex Generator Positions

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4258772
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorQiang, Wang
    contributor authorZuoqin, Qian
    contributor authorJunlin, Cheng
    contributor authorJie, Ren
    contributor authorWeilong, Huang
    date accessioned2019-09-18T09:05:36Z
    date available2019-09-18T09:05:36Z
    date copyright7/22/2019 12:00:00 AM
    date issued2019
    identifier issn0022-1481
    identifier otherht_141_09_091804
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258772
    description abstractThe numerical simulation was carried out to investigate mechanism of the heat transfer enhancement in the fin-and-tube heat exchangers. As known, the vortex generators (VGs) were widely used to improve the thermal performance with bad flow resistance characteristics and led to bad comprehensive performance. This paper aims to expound the mechanism of thermal hydraulic characteristics and explore the effect of VGs position on the comprehensive performance. Three types of fins (type 1, type 2, and type 3) were discussed in this paper. The j factor, f factor, and performance evaluation (PEC) of three types of VGs in different positions were discussed and compared. Based on the numerical results, a detailed description of the effect of three types of VGs on the heat transfer performance and flow resistance characteristics was presented at different Reynolds number in the range between 1300 and 2000. In addition, local velocity distribution, local temperature distribution, and local pressure drop distribution were analyzed and discussed. And the effect of VG angle on the thermal performance and flow resistance was presented. It can be concluded that the main heat transfer occurred in the region before the tube, and the wake region behind the tube was harmful to improve the thermal performance and reduce the flow resistance. Besides, VG in the wake region was obviously beneficial to the enhancement of the thermal performance with less energy loss.
    publisherAmerican Society of Mechanical Engineers (ASME)
    titleInvestigation on Heat Transfer Performance and Flow Resistance Characteristics in Finned-Tube Heat Exchangers With Different Vortex Generator Positions
    typeJournal Paper
    journal volume141
    journal issue9
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4042008
    journal fristpage91804
    journal lastpage091804-10
    treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian