    A NOVEL MICROLASER BASED PLASMONIC-POLYMER HYBRID RESONATOR FOR MULTIPLEXED BIOSENSING APPLICATIONS

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2019:;volume( 002 ):;issue: 002
    Author:
    Manzo, Maurizio
    ,
    schwend, ryan
    DOI: 10.1115/1.4042377
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Whispering gallery mode (WGM) resonators exhibit a high quality factor Q and a small mode volume; they usually exhibit high resolution when used as sensors. The light trapped inside a polymeric micro-cavity travels through total internal reflection generating the whispering gallery modes (WGMs). A laser or a lamp is used to power the microlaser by using a laser dye embedded within the resonator. The excited fluorescence of the dye couples with the optical modes. The optical modes (laser modes) are seen as sharp peaks in the emission spectrum with the aid of an optical interferometer. The position of these optical modes is sensitive to any change in the morphology of the resonator. However, the laser threshold of these microlasers is of few hundreds of microjoules per square centimeter (fluence) usually. In addition, the excitation wavelength's light powering the device must be smaller than the microlasers size. When metallic nanoparticles are added to the microlaser, the excited surface plasmon couples with the emission spectrum of the laser dye. Therefore, the fluorescence of the dye can be enhanced by this coupling; this in turn, lowers the power threshold of the microlaser. Also, due to a plasmonic effect, it is possible to use smaller microlasers. In addition, a new sensing modality is enabled based on the variation of the optical modes' amplitude with the change in the morphology's microlaser. This opens a new avenue of low power consumption microlasers and photonics multiplexed biosensors.
    • Download: (3.346Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A NOVEL MICROLASER BASED PLASMONIC-POLYMER HYBRID RESONATOR FOR MULTIPLEXED BIOSENSING APPLICATIONS

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4256680
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorManzo, Maurizio
    contributor authorschwend, ryan
    date accessioned2019-03-17T11:07:02Z
    date available2019-03-17T11:07:02Z
    date copyright12/22/2018 12:00:00 AM
    date issued2019
    identifier issn2572-7958
    identifier otherjesmdt-18-1038.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256680
    description abstractWhispering gallery mode (WGM) resonators exhibit a high quality factor Q and a small mode volume; they usually exhibit high resolution when used as sensors. The light trapped inside a polymeric micro-cavity travels through total internal reflection generating the whispering gallery modes (WGMs). A laser or a lamp is used to power the microlaser by using a laser dye embedded within the resonator. The excited fluorescence of the dye couples with the optical modes. The optical modes (laser modes) are seen as sharp peaks in the emission spectrum with the aid of an optical interferometer. The position of these optical modes is sensitive to any change in the morphology of the resonator. However, the laser threshold of these microlasers is of few hundreds of microjoules per square centimeter (fluence) usually. In addition, the excitation wavelength's light powering the device must be smaller than the microlasers size. When metallic nanoparticles are added to the microlaser, the excited surface plasmon couples with the emission spectrum of the laser dye. Therefore, the fluorescence of the dye can be enhanced by this coupling; this in turn, lowers the power threshold of the microlaser. Also, due to a plasmonic effect, it is possible to use smaller microlasers. In addition, a new sensing modality is enabled based on the variation of the optical modes' amplitude with the change in the morphology's microlaser. This opens a new avenue of low power consumption microlasers and photonics multiplexed biosensors.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA NOVEL MICROLASER BASED PLASMONIC-POLYMER HYBRID RESONATOR FOR MULTIPLEXED BIOSENSING APPLICATIONS
    typeJournal Paper
    journal volume2
    journal issue2
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4042377
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2019:;volume( 002 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian